Command Descriptions
TDS Family Oscilloscope Programmer Manual
2–261
TRIGGER:MAIN:PULSE:SLEWRATE:THRESHOLD:LOW 50E-3
sets the lower limit of the pulse slew rate trigger to 50 mV.
TRIGger:MAIn:PULse:SLEwrate:WHEn
TDS 684A & 7XXA Only
Sets or queries whether to check for a slewing signal that is faster or slower than
the specified delta time. This is equivalent to to selecting Trigger When from
the main Triggers Slew Rate menu and entering a value in the resulting side
menu’s Trig if Less Than or Trig if Greater Than items.
Trigger
TRIGger:MAIn:PULse:SLEwrate:WHEN { FASTERthan | SLOWERthan }
TRIGger:MAIn:PULse:SLEwrate:WHEN?
FASTERthan
TRIGger :
:
PULse
MAIn :
:
WHEN
SLEwrate
SLOWERthan
<Space>
?
FASTERthan sets the trigger to occur when the slew is faster than the set
volts/second rate.
SLOWERthan sets the trigger to occur when the slew is slower than the set
volts/second rate.
TRIGGER:MAIN:PULSE:SLEWRATE:WHEN FASTERTHAN
sets the slew rate trigger to work when the slew is faster than the set volts/second
rate.
TRIGger:MAIn:PULse:SOUrce
TDS 5XXA, 6XXA, & 7XXA Only
Sets or queries the source for the main pulse trigger. This is equivalent to
selecting the source in the Pulse Runt Source side menu.