Manual Door intercom devices a / b series 20 / 30 / 40 / 50 / 20-0028A/-0028B
Connection
GB
67www.behnke-online.com
a / b series 20 / 30 / 40 / 50 / 20-0028A/-0028B door intercom manual
Connection
D
Quick set-up (code, value, confirmation)
(Always check with the operator)
Connect the telephone line: during the initialisation,
there is a high-pitch beep for approx. 10 seconds.
Enter set-up mode: *, 0000
Enter telephone numbers
first telephone number: 21, telephone number, #
second telephone number: 22, telephone number, #
third telephone number: 23, telephone number, #
up to the ninth telephone number: 29, telephone number, #
Activate group calling,
number of telephone numbers to be dialled: 20, 1 to 9, #
(Please note: the call reception terminal station
has to acknowledge the call with a DTMF tone)
Volume control (optimum setting = 7) 06,
1 97
, #
Non-isolated button at alarm input: 17, 6, #
Activation of the 900-parameters: 900, 1, #
Echo suppressor damping (remove acoustic feedback): 911, 15 to 20, #
Microphone level: 913, 1 to 7, #
Cabin button: Closing contact (standard) 970, 0, #
Cabin button: Opening contact 970, 1, #
(Please note: this configuration section must be activated
before connecting the opening contact)
Deactivation of the 900-parameters: 900, 0, #
Exit set-up mode: *