Manual Door intercom devices a / b series 20 / 30 / 40 / 50 / 20-0028A/-0028B
Configurations and Set-up
GB
79www.behnke-online.com
Code Parameter Conrmation
With version 1.30 or later:
*4 x Condition
x=0 Always
x=1 Current time within schedule 1 (only makes sense with a clock
module in use)
x=2 Current time within schedule 2 (only makes sense with a clock
module in use)
x=3 Current time not within schedule 1 (only makes sense with a
clock module in use)
x=4 Current time not within schedule 2 (only makes sense with a
clock module in use)
x=5 For technical alarm (only makes sense with configuration step
17>0 )
x=6 For non-technical alarm (only makes sense with configuration
step 17>0 )
x=7 If alarm input is enabled (only makes sense with configuration
step 17>0 )
x=8 If alarm input is disabled (only makes sense with configuration
step 17>0)
x=9 Else (only makes sense with other *4x conditions having been
set)
*5 x Play message no. x (only makes sense with a message module
in use)
*5 0 Play signal sequence
*6 x Display text no. x (only makes sense with a display module in
use)
*7 x Activate relays (1=Relay 1, 2=Relay 2, 3=Relays 1&2)
*8 x y Wait for the call to be answered (x=voice message to be played
while waiting for the call to be answered and y=voice message
to be played after the call has been answered) (only makes
sense with an extension module in use)
*9 x pointer to telephone number (x=1...9)
*9 0x pointer to speed dial (x=00...99)
** x individual group call (x=1=...9=next telephone number)