Manual Door intercom devices a / b series 20 / 30 / 40 / 50 / 20-0028A/-0028B
Configurations and Set-up
GB
80 www.behnke-online.com
Code Parameter Conrmation
** 0 Hotline function
*# Flash function
** ** stop dialling
** *0 Mute off
** *1 Mute on
With version 1.34 or later:
*4** 1 in case relay 1 is activated
*4** 2 in case relay 2 is activated
*4* x y check a variable (condition) (x=0..9, y=0..9) x=y?
The condition is fulfilled if value x equals value y.
*5* x y set a variable (x=0..9, y=0..9) x:=y
sets the variable x to value y
*5** x increment variable (x=0..9) x++
increments the variable x (for x=9, the x++=0)
*6* 0 disable the timer
*6* x mm direct call button x (x=1..9) activate after mm (mm=00..99)
minutes
*74 Disable Relay 1 (only for operations mode 18)
*75 Enable Relay 1 (only for operations mode 18)
*76 Disable Relay 2 (only for operations mode 18)
*77 Enable Relay 2 (only for operations mode 18)
300
301
:
399
Speed dialling key: Default: cf. text
Speed dial Speed dialling key 00
Speed dial Speed dialling key 01
Speed dial Speed dialling key 99
#
#
:
#
900
Advanced configurations: Default setting: 0
0 = disabled
1 = enabled
The following configuration may only be adjusted with enabled extended