Transmit Mode “Non-continuous transmitting mode”: After “Power-
transmitter will transmit the signal only when the pushb
pressed. This mode can save the power of transmitter.
“Continuous transmitting mode”:
Transmitter will continuously
transmit signal once transmitter is being Power-On.
Save Power This function is used to turn off the Transmitter after a given idle
time. *Only available under “continuous transmitting” mode.
Auto-OFF(TX)
This function refers to turn off the Transmitter after a given idle
time while transmitting the signal to switch off the receiver main
relay. *Only available under “continuous transmitting” mode.
LED OFF-Time This setting
allows you to select the LED intermittent time to save
transmitter power. i.e.: If 1 second is selected, the LED will be
lighted every 1 second.
Passive Act This function ensures safe operations, including when
disturbances
that may affect the normal operating conditions. This
assures that when the machine operates, the control is not subject
to temporary and unexpected stops. Possible short interferences
are bypassed. The passive act can be select in 2 mode as below,
“Ry Off”
If the interferences are larger than the pre-
receiver will turn off all the relays under “NORMAL”
except the MAIN relay.
“Power-Off”
If the interferences are larger than the pre-
the receiver will turn off all the relays under “NORMAL”
function and “Control by EMS”
including MAIN relay. The
receiver must be restart to operate again, follow the “Power-On”
procedure to restart the system.
Passive EMS This setting allows the user to select the duratio
interferences to be bypassed. If the interferences were within the
duration, then the receiver is still in operation, not affected
the interference is longer than the duration, then the receiver will
stop working. Usually, this action is called “Passive EMS”.
AUTO OFF (RX) This function refers to turn off receiver after a given idle time.
Receiver MAIN relay will be turned off
this function is cooperated with “non-continuous “transmitting”
mode to prevent any unintentional radio.