27
Start-Alarm This function
allows the user to activate the alarm of the receiver
to work or not to work. If the “Enable (2 sec)”
is chosen, then the
alarm will make a 2-
second sound when the receiver is powered
on/off.
TxPower(Range) The e
mission power of the transmitter is adjustable according to
the user’
s requirement. This options is shown as transmission
distance ranging from 20m to 500m, 8 steps to choose.
The transmission distance is strictly subject to the local
environmental factors
. Therefore, it might be different from place
to place and it is for reference only.
Jam Detect This function is to allow the user to activate the
relay jam detect
circuit
of the motion relays, UP/DOWN, EAST/WEST,
SOUTH/NORTH, or not.
If the option “Enable”
is chosen, then the circuit is activated and
it will control the EMS relay to stop working when the jammed
relay is detected.
Remote Channel
Changing
When the option “Enable” is chosen, then the
Remote Channel
Changing” is allowed to perform. See Section 3-5-
1 for the
procedure of remote setting. When the option “Disable”
is chosen,
then theRemote Channel Changing” cannot be performed.
Remote Pairing When the option “Enable” is chosen, then the “Remote Pairing”
is
allowed to perform. See Section 3-5-
2 for the procedure of remote
setting. When the option “Disable” is chosen, then the
Remote
Pairing” cannot be performed.
Channel This setting allows the user to choose
the Operating Frequency
for the remote controller. There are 70 channels in to
tal can be
selected, CH1~CH70.