Homeowner's Installation and
Operating Manual
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
Direct Vent Zero Clearance
Gas Fireplace Heater
Models: DV1000MBN
DV1200MBN
DV1400MBN
76658 7/04 Rev. 29
DO NOT STORE OR USE GASO-
LINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY
OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
Immediately call your gas
supplier from your neighbor's
phone. Follow the gas suppliers
instructions.
If you cannot reach your gas
supplier call the fire department.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
INSTALLER/CONSUMER
SAFETY INFORMATION
FOR YOUR SAFETY
Installation and service must be
performed by a qualified in-
staller, service agency or the
gas supplier.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Refer to this
manual. For assistance or additional
information, consult a qualified
installer, service agency or the gas
supplier.
U.S. Patents: 5,669,374; 5,562,088; 6,138,667: Can. Patent: 2,139,684
C US
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
CFM Specialty Home Products

Questions and Answers

  • M
    Michael ChapmanAug 8, 2025
    What to do if there is no gas to main burner in Temco DV1000MBN Indoor Fireplace?
    • J
      Joshua Luna MDAug 8, 2025
      If there is no gas to the main burner of your Temco Indoor Fireplace, it could be due to several reasons: * Low gas pressure: Adjust the inlet pressure regulator to supply gas within the manufacturer's design parameters (typically 7”NG, 11”LPG) with the main burner functioning. * Pilot not lit: Light the pilot and wait for the thermo-generator to heat up. If the pilot fails to light or hold, consult the relevant sections in the manual. * Control knob position: Ensure the OFF/PILOT/ON control knob is in the ON position.
  • J
    Julie OwensAug 21, 2025
    How to troubleshoot thermo-generator output voltage on Temco DV1000MBN?
    • S
      stewartteresaAug 21, 2025
      If the thermo-generator output voltage of your Temco Indoor Fireplace is not within design parameters, after lighting the pilot for about three minutes with only the thermo-generator wire connected, measure the voltage across TPTH and TP. The open circuit voltage should be between 500mV and 750mV. Adjust the pilot adjustment screw until the mV reading falls within these parameters (counter-clockwise increases mV, clockwise decreases). If you can't meet the minimum requirements, replace the thermo-generator.
  • J
    Jonathan EllisAug 26, 2025
    Why Temco DV1000MBN thermostat/wall switch will not cycle main burner?
    • A
      Adam HuertaAug 26, 2025
      If the thermostat/wall switch of your Temco Indoor Fireplace will not cycle the main burner because of a defective wall switch, repeat the troubleshooting steps covered under “Defective thermostat or thermostat wiring”, but substitute the words “wall switch” where the word “thermostat” appears in the instructions. Also, check the following: * Excessive wire resistance: Make certain that all mV connections are made using wire of the proper size. * Valve wiring: Thermo-generator leads must be connected to the TPTH and TP connections of the main operator. Thermostat wires must be connected to the TPTH, and TH terminals of the valve.
  • J
    Justin CastanedaAug 29, 2025
    Why main burner lights in the PILOT position on Temco DV1000MBN Indoor Fireplace?
    • J
      Joseph WilliamsAug 30, 2025
      If the main burner of your Temco Indoor Fireplace lights in the PILOT position, there could be a few reasons: * Main operator coil defective: Remove all wires from the operator head. Measure electrical resistance between TP and TH terminals with an Ohm meter. If the resistance doesn't meet specifications, replace the valve. * Debris on the seat of the main valve: Replace the valve. * Main seat blown out: Replace the valve if the main seat is blown out due to unregulated LPG line pressure exceeding 15 PSI.
  • K
    Kimberly MartinSep 3, 2025
    What to do if Temco DV1000MBN Indoor Fireplace pilot orifice blocked?
    • D
      duncanbarrySep 3, 2025
      To resolve a blocked pilot orifice in your Temco Indoor Fireplace, replace the existing orifice with a new one that is exactly the same size and type.
  • M
    Mary WilsonNov 12, 2025
    Why Temco DV1000MBN Indoor Fireplace pilot will not light?
    • H
      Heather MoyerNov 12, 2025
      If the pilot light of your Temco Indoor Fireplace won't light, here are a few potential causes and solutions: * Air in gas lines: Bleed all air from the gas lines. * Defective spill switch: Check for continuity across the spill switch leads. Replace the spill switch if there's excessive resistance or an open circuit. * Wrong inlet pressure: With the main burner functioning, adjust the inlet pressure regulator to supply gas within the appliance's design parameters (typically 7”NG, 11”LPG). * Defective spark electrode: Replace the piezo wire if the insulation is cracked or the tip is corroded. Verify the spark gap between the pilot and the electrode is correct. * Defective piezo wire: Replace the piezo wire if the insulation is damaged, or the wire is broken or corroded. * Safet...
  • R
    reyeschristopherNov 16, 2025
    Why Temco Indoor Fireplace pilot will not hold?
    • B
      Benjamin WilsonNov 16, 2025
      If the pilot light on your Temco Indoor Fireplace won't hold, consider these potential causes and solutions: * Wrong inlet pressure: With the main burner functioning, adjust the inlet pressure regulator to supply gas within the appliance's design parameters (typically 7”NG, 11”LPG). * Pilot adjustment screw: After the pilot has been lit for about three minutes with only the thermo-generator wire connected, measure the voltage across TPTH and TP. It should be between 500mV and 750mV. Adjust the pilot adjustment screw until the reading falls within this range (counter-clockwise increases mV, clockwise decreases). * Thermocouple/thermo-generator insertion: Ensure the thermocouple and thermo-generator are fully inserted and tightened into their receptacles in the pilot head. The thermoc...