11
8232E 8204S
ELBOW FLUE
" X" OFFSET "Y" RISE SET 12" 18" 36" 48" SUPPORT
8-7/8" 23-1/4" 1 1 0 0 0 -
11-7/8" 28-1/2" 1 0 1 0 0 -
13-7/8" 31-7/8" 1 2 0 0 0 -
16-7/8" 37-1/8" 1 1 1 0 0 -
20-7/8" 44" 1 0 0 1 0 -
26-7/8" 54-1/2" 1 0 0 0 1 -
28-7/8" 57-7/8" 1 0 1 1 0 -
31-7/8" 63-1/8" 1 1 0 0 1 -
34-7/8" 68-3/8" 1 0 1 0 1 -
36-7/8" 71-3/4" 1 2 0 0 1 -
39-7/8" 80-1/4" 1 1 1 0 1 1
43-7/8" 87-1/8" 1 0 0 1 1 1
49-7/8" 97-5/8" 1 0 0 0 2 1
51-7/8" 101" 1 0 1 1 1 1
54-7/8" 106-1/4" 1 1 0 0 2 1
57-7/8" 111-1/2" 1 0 1 0 2 1
59-7/8" 114-7/8" 1 2 0 0 2 1
62-7/8" 120-1/8" 1 1 1 0 2 1
66-7/8" 127" 1 0 0 1 2 1
71-7/8" 135-5/8" 1 1 0 1 2 1
72-7/8" 137-1/2" 1 0 0 0 3 1
74-7/8" 140-7/8" 1 0 1 1 2 1
77-7/8" 149-3/8" 1 1 0 0 3 2
80-7/8" 154-5/8" 1 0 1 0 3 2
82-7/8" 158" 1 2 0 0 3 2
85-7/8" 163-1/4" 1 1 1 0 3 2
89-7/8" 170-1/8" 1 0 0 1 3 2
94-7/8" 178-3/4" 1 1 0 1 3 2
95-7/8" 180-5/8" 1 0 0 0 4 2
97-7/8" 184" 1 0 1 1 3 2
100-7/8" 189-1/4" 1 1 0 0 4 2
103-7/8" 194-1/2" 1 0 1 0 4 2
105-7/8" 197-7/8" 1 2 0 0 4 2
108-7/8" 203-1/8" 1 1 1 0 4 2
112-7/8" 213-1/4" 1 0 0 1 4 3
117-7/8" 221-7/8" 1 1 0 1 4 3
118-7/8" 223-3/4" 1 0 0 0 5 3
120-7/8" 227-1/8" 1 0 1 1 4 3
125-7/8" 232-3/8" 1 1 0 0 5 3
126-7/8" 237-5/8" 1 0 1 0 5 3
TO "Y" DIMENSION ADD 39" FOR TFC/TLC3922 FIREPLACES
TO "Y" DIMENSION ADD 6" FOR 8203D TERMINATION CAP
OFFSET AND RISE CHART
Number Of
Chimney Lengths
(NOT INCLUDING FIREPLACE OR TERMINATION CAP)
INCLUDING ONE SET OF ELBOWS AND FLUE SUPPORTS AS NEEDED
Chimney Only (inches)
Height Of