Owner’s Manual
Models: TC-12B - TC-60B4, Digital Thermostat
Unit Specifications .......................................................................................... 2
Rating Information ........................................................................................... 2
Inspection ......................................................................................................... 3
General Description ......................................................................................... 3
Standard Features .......................................................................................... 3-4
Optional Features ............................................................................................. 4
Installation Instructions .................................................................................4-5
Unit Operation ..............................................................................................5-6
Preventative Maintenance ............................................................................. 6-7
Troubleshooting Guide .................................................................................8-9
Installing Replacement Parts ....................................................................10-11
Accessories .................................................................................................... 12
Replacement-Parts List .............................................................................13-14
Wiring Schematic, TC-12B ........................................................................... 15
Wiring Schematic, TC-18B ........................................................................... 16
Wiring Schematic, TC-24B ........................................................................... 17
Wiring Schematic, TC-36B ........................................................................... 18
Wiring Schematic, TC-60B ........................................................................... 19
Wiring Schematic, TC-60B3 ......................................................................... 20
Wiring Schematic, TC-60B4 ......................................................................... 21
1-800-836-7432
Warning!
Improper installation, adjust-
ment, alteration, service, or
maintenance can cause injury
or property damage. Please
read instructions before install-
ing, operating or servicing the
TEMP-COOL unit.
Avertissement !
Le fait de modier ou de mal
installer, régler, réparer ou
entretenir cet appareil peut
entraîner des blessures ou des
dommages matériels. On doit
lire attentivement les directives
d’installation, d’utilisation et
d’entretien avant de manipuler
l’unité TEMP-COOL
This manual is the property
of the owner. Leave with the
unit when set-up and start-up
are complete. TEMP-AIR
Inc. reserves the right to
change design and specica-
tions without prior notice.

Questions and Answers

  • G
    george24Jul 31, 2025
    Why my Temp-Cool TC-18B Thermostat unit does not run?
    • D
      David LewisJul 31, 2025
      If your Temp-Cool Thermostat is not running, start by checking the external power supply and reset the LCDI cord control. Inspect the circuit breakers and fuses, replacing or resetting them if needed. Also, verify that the condensate tank is not full, and empty it if it is. Ensure the thermostat is set correctly, comparing the mode and temperature setpoint to the room temperature, and reset if necessary. Check the thermostat display and test its responsiveness by pressing the power and mode switches; replace the thermostat if it doesn't respond. Finally, address any error codes displayed, such as rE, FE, CF, Fr, or tF, by repairing or replacing the indicated sensor or component, checking for compressor problems, or emptying the condensate tank.
  • J
    Jodi SanchezAug 15, 2025
    How to fix a noisy Temp-Cool TC-18B?
    • K
      Katherine BaileyAug 15, 2025
      If your Temp-Cool Thermostat is operating noisily, check the compressor rotation, changing it if necessary. Inspect all panels and components to ensure they are securely fastened, including motors, blower wheels, drives, bearings, and shafts, tightening as needed. If the noise persists, the motor, compressor, or bearing may be faulty and require replacement.
  • E
    Elizabeth LambertAug 20, 2025
    What to do if Temp-Cool TC-18B Thermostat is leaking water?
    • D
      Daniel HowardAug 20, 2025
      If you notice water leaking from the pan of your Temp-Cool Thermostat, start by checking the connections of the evaporator, drain, or condensate pump hose and tighten them if necessary. Inspect the drain pan for any blockages and remove any obstructions. If the drain pan itself is leaking, repair or replace it. Also, examine the condensate pump for defects, check the condensate hose for obstructions, and ensure the discharge tube height is not excessive (12 ft. max.). Clear or reroute the tube as required, and if necessary, replace the pump and its wiring.
  • E
    evansannaAug 25, 2025
    Why does Temp-Cool TC-18B Thermostat evaporator coil keep freezing?
    • B
      btaylorAug 26, 2025
      If the evaporator coil in your Temp-Cool Thermostat is freezing and the unit shuts down, first check for any obstructions to the evaporator airflow and clean the filter and coil if needed. Also, ensure that the freeze sensor is properly mounted to the coil to allow the thermostat's freeze protection to function correctly.
  • J
    Julie PruittNov 4, 2025
    What to do if Temp-Cool TC-18B compressor runs but condenser fan doesn't?
    • J
      Jack WangNov 4, 2025
      If your Temp-Cool Thermostat's compressor runs but the condenser fan doesn't, and you're experiencing insufficient cooling, first trace and repair any loose or defective wires. Then, replace any shorted or open condenser motor capacitor. If these steps don't resolve the issue, the motor may be bad and require replacement. Additionally, check for insufficient airflow through the evaporator coil, which may be due to improper blower rotation, a dirty air filter or evaporator coil, an obstructed air intake, ice on the evaporator coil, or low refrigerant. Correct these issues by checking the rotation, replacing the filter, cleaning the coil, removing any obstructions, defrosting the coil, or repairing any leaks and recharging the refrigerant. Lastly, ensure the unit is properly sized for the lo...
  • N
    Nicholas MartinezNov 9, 2025
    Why is my Temp-Cool Thermostat evaporator fan running but not the compressor?
    • L
      lozanochristopherNov 9, 2025
      If your Temp-Cool Thermostat's evaporator fan runs, but the compressor and condenser fan do not, it could be due to several reasons. The evaporator fan runs anytime the thermostat is on, the compressor and condenser only run if there is a demand for cooling. Ensure the thermostat is calling for cooling and wait at least five minutes for the compressor to start, as it might be in a start delay mode. Verify that the thermostat is set to the 'COOL' mode. Check that the condensate jumper plug or condensate pump is properly installed. Also, check the high-pressure switch, and press the reset button, replacing the switch if necessary. Inspect for loose or defective wires, securing contacts or replacing wires as needed. Replace a shorted or open run capacitor. If none of these resolve the issue, ...

Summary

Unit Specifications and Rating Information

Standard Features

High-Pressure Safety Switch

Manual reset switch for refrigeration circuit protection.

Digital Temperature Control System

User interface for mode selection, temperature, and timing.

Installation Instructions

Pre-Installation Checks and Guidance

Steps and checks required before unit installation.

Electrical Supply and Wiring

Guidance on power supply and wiring for different models.

Unit Operation

Cooling Mode Operation

Step-by-step instructions for operating in cooling mode.

Preventive Maintenance Procedures

Preventive Maintenance Details

Troubleshooting Guide

Unit Fails to Run Troubleshooting

Diagnosing and resolving issues when the unit does not operate.

Fan Operates, Compressor;Condenser Fan Do Not

Troubleshooting when only the evaporator fan is active.

Troubleshooting Common Issues

Installation of Accessories and Parts

Replacement Parts List - Components

Replacement Parts List - Controls and Hardware

Wiring Schematic - TC-12 B

Wiring Schematic - TC-18 B

Wiring Schematic - TC-24 B

Wiring Schematic - TC-36 B

Wiring Schematic - TC-60 B

Wiring Schematic - TC-60 B3

Wiring Schematic - TC-60 B4