13
TEMP-HEAT
®
Shut-Down Steps
Short-Term Shut Down
• Turn burner switch to OFF position.
• Wait 30-sec.
• Turn blower switch to OFF position.
• Look to see that flame is extinguished.
Extended Shut-down or Disconnection of Unit
• With unit running, close vapor-fuel supply valve at vaporizer. (Propane installation only.)
Caution: Do not close liquid supply valve while vaporizer is ON. See vaporizer for proper
operation of vaporizer. Contact your gas company for further information on safe handling
of propane vaporizers.
• Allow heater to run until flame-safety light goes ON, indicating that all gas has been burned
from gas lines.
Caution: Check to see that pilot light on vaporizer is extinguished before disconnecting gas lines.
• Turn burner switch OFF.
• Continue running blower until no flame exists in the base of the burner.
• Turn the blower switch OFF.
• Turn power OFF at source and disconnect electrical lines.
• Disconnect propane-vapor line from heater.
• Contact gas company to disconnect vaporizer.