(c/w EC Motor and UC7 Controller versions)



 - A general designation which
applies to all versions (refer g.1)
These HWP units must be installed in
accordance with all national and local safety
codes.

The following items are available as optional
extras:
1. Condensate Lift-Pump Kit.
2. Filter Box.
A remote return air temperature sensor is
supplied on all models except for
HWP 77/96 CEKSYD models. Optional
sensors are available; refer page 3.
High pressure hoses (600 mm long) c/w
tting and spring mounts are supplied as
standard.

As air ltration requirements vary, lters are
not supplied with the unit. Filters should
ideally be installed on the return air side of
the unit, no closer than 500 mm from the
back of the unit and easily accessible for
cleaning. To maximise the efciency of air
ow, the return air lter should be twice the
area of the HWP unit's return air spigot/s. If
efciency is less of a concern a Filter Box is
available.
The Filter Box is installed by unscrewing
the return air spigot and replacing it with the
Filter Box's lter-integrated spigot. The lter
may be accessed from either side of this
spigot. This box adds 245 mm to the overall
depth of the unit.


HWP units are designed to be used with
simple, short duct layouts. Units should
be located as close to the space to be air
conditioned as acoustic criteria allows; refer
to Fig. 6 for application considerations.
When determining the position of the air
conditioner, allow adequate space around
the unit to facilitate future servicing and
maintenance. Ensure there is enough
working space in front of the electrical
access panel. Allow adequate clearance for
the lter (optional) to be withdrawn to its full
length.






Not to Scale
C - Cooling only
CE - Cooling only with electric heat
R - Reverse cycle
K - Refrigerant R410A
S - Single phase power supply
Y - EC fan motor
T - Three phase power supply
D - Integrated Thermostat
N - Protection board
H
H - Hideaway
W - Water Sourced
P - Packaged
Divide by 10
to get approx.
nominal
Capacity in
kilowatts
Series Size Type
Nomenclature
CW P 7 7 K
e.g.
S Y D

1179
HANGING CENTRES
20 X 9 SLOTS
1305
OVERALL
ACCESS
PANEL
DRAIN 19 OD
WATER CONN'S:
TWO BSP MALE
19 mm (3/4")
ELECTRICAL
BOX
ELECTRICAL
CONDUIT
HOLES
710
SUPPLY AIR SPIGOT
200
440
HANGING
CENTRES
SLOPING DRAIN TRAY
416
OVERALL
480
OPTIONAL
SPRING MTG
CENTRES
1255
OPTIONAL
SPRING MOUNTING CENTRES
70
85
75
90
OPTIONAL
R/A FILTER BOX WITH
FILTER ACCESS
EACH SIDE
OPTIONAL
FILTER BOX
698
(HEIGHT = 340)
IN
OUT
(WATER)
30
725
OVERALL
65
245
PROJECTION

HWP 77 117 kg
HWP 96 120 kg