Lists available optional components: Filter Box, Spring Mounting Kit, and Electric Heater Box.
Details the installation and access method for the filter box option.
Describes the installation procedure for the electric heater box option.
Instructions for unpacking and inspecting the unit for transit damage.
Guidelines for unit positioning, clearance, and recommended mounting methods.
Details requirements for condensate drain trap, slope, and venting.
Instructions for piping and wiring connections between indoor and outdoor units.
Specifies pipe connection sizes and types for refrigerant lines.
Details electrical supply, wiring diagrams, and safety precautions.
Guidance on selecting appropriate fan speeds based on conditions.
Information on thermostat options and dedicated neutral line requirements.
Recommends fan speed controller for cooling in low ambient conditions.
Steps for checking thermostat, filter, fan, and drain during commissioning.
Weekly maintenance checks for the first four weeks of operation.
Monthly and six-monthly maintenance tasks for the unit.
Warning about using only HCFC-22 refrigerant and risks of others.
Advice for minimizing noise, especially in high static installations.
Diagram showing electrical connections for the ISD 220Q unit.
Details on how to change fan speed selection via wire connections.
Lists internal components like capacitors, relays, and fan motors.
Notes on interconnections between units made by the client.
Diagram showing electrical connections for the ISD 265Q unit.
Lists internal components and their specifications for the ISD 265Q.
Notes the replacement of a previous issue and specific revisions.
Lists available optional components: Filter Box, Spring Mounting Kit, and Electric Heater Box.
Details the installation and access method for the filter box option.
Describes the installation procedure for the electric heater box option.
Instructions for unpacking and inspecting the unit for transit damage.
Guidelines for unit positioning, clearance, and recommended mounting methods.
Details requirements for condensate drain trap, slope, and venting.
Instructions for piping and wiring connections between indoor and outdoor units.
Specifies pipe connection sizes and types for refrigerant lines.
Details electrical supply, wiring diagrams, and safety precautions.
Guidance on selecting appropriate fan speeds based on conditions.
Information on thermostat options and dedicated neutral line requirements.
Recommends fan speed controller for cooling in low ambient conditions.
Steps for checking thermostat, filter, fan, and drain during commissioning.
Weekly maintenance checks for the first four weeks of operation.
Monthly and six-monthly maintenance tasks for the unit.
Warning about using only HCFC-22 refrigerant and risks of others.
Advice for minimizing noise, especially in high static installations.
Diagram showing electrical connections for the ISD 220Q unit.
Details on how to change fan speed selection via wire connections.
Lists internal components like capacitors, relays, and fan motors.
Notes on interconnections between units made by the client.
Diagram showing electrical connections for the ISD 265Q unit.
Lists internal components and their specifications for the ISD 265Q.
Notes the replacement of a previous issue and specific revisions.
| Model | ISD 220Q |
|---|---|
| Refrigerant | R410A |
| Operating Temperature (Cooling) | 18°C to 46°C |
| Operating Temperature (Heating) | -15°C to 24°C |
| Energy Efficiency Rating | 3.5 |
| Power Supply | 220-240V, 50Hz |