OPA 970RLTB2FPQD(-Z) (Econex Pro)
Air Cooled Packaged Units - Reverse Cycle - R32
Installation & Maintenance
CONTENTS Page
1. GENERAL ..............................................................................1
2. INSTALLATION ......................................................................2
3. REFRIGERATION SYSTEM ...................................................2
4. WIRING ..................................................................................3
5. ECONOMISER .......................................................................3
6. START-UP PROCEDURE ......................................................3
7. O PER ATI ON ...........................................................................7
8. MAINTENANCE .....................................................................9
9. TROUBLESHOOTING ...........................................................9
10. WARRANTY .........................................................................9
APPENDIX I : CONTROLS SET-UP IP ADDRESS ................10
APPENDIX II : MASTER CONTROLLER - SYSTEM INFO .....11
APPENDIX III : UC8 PROTECTION FUNCTIONS ...................12
APPENDIX IV: AIR HANDLING PERFORMANCE ................14
COMMISSIONING CHECK LIST .............................................15
1. GENERAL
Temperzone OPA Outdoor Air Cooled Packaged units.
Follow these instructions to ensure the optimum performance,
reliability and durability.
Units must be installed in accordance with all national and
regional regulations and bylaws. National Health and Safety
regulations must be followed to avoid personal injuries.
The appropriate local permits must be acquired and
adhered to.
Local regulations on maximum boundary noise need to
be considered when positioning the unit.
The accompanying ‘R32 Handling Ducted Packaged Units’
pamphlet forms part of these Installation & Maintenance
instructions.
! WARNING
These units use R32 refrigerant (Class A2L) which is mildly
ammable.
The system shall be installed, operated and stored in a well
ventilated space. If the refrigerant gas comes into contact with
re, a poisonous gas may occur. Be aware that R32 does not
contain an odour.
If indoors, the appliance shall be stored in a room away from
continuously operating sources known to cause ignition of R32
refrigerant (for example an operating gas appliance or operating
electric heater)
2. INSTALLATION
2.1 Clearances & Service Access
Refer to Specication Sheet supplied for minimum
clearances. If multiple units are to be placed side-by-side
then allow at least 2m between coil faces.
Filter slides are tted within the unit. Access to the lter
access door should be considered when designing return
and supply air ductwork.
2.2 Mounting
The unit should be fastened to a rm at horizontal base
using the holes supplied in the mounting channels. When
the unit is being installed on a roof it is recommended that
the unit is installed on a substantial structure with vibration
isolating pads or mounts. If placed on the ground or
concrete pad, use rubber pads or mounts to give 20mm min.
ground clearance.
Flexible duct connections are recommended between the
supply and return ducts and the unit.
Unit is shipped with plastic wedges installed under the
compressors. Ensure these wedges are removed from
the compressor feet prior to starting the unit
(not required for operation).
003-000-286 03/23
Question and Answer IconNeed help?

Do you have a question about the TemperZone Econex Pro and is the answer not in the manual?

Summary

1. GENERAL

R32 Refrigerant Warning

Alerts users to the mild flammability of R32 refrigerant and necessary precautions.

2. INSTALLATION

Clearances and Service Access

Details necessary space around the unit for proper installation and maintenance access.

4. WIRING

Electrical Requirements and Safety

Outlines electrical connection requirements and essential safety precautions for qualified personnel.

BMS - BACnet Interface

Instructions for connecting and configuring the unit for BACnet communication.

Wiring (Continued)

BMS - Modbus Connection

Guidance on establishing Modbus communication for unit control and monitoring.

6. START-UP PROCEDURE

Pre-Startup Compressor Checks

Essential checks before starting compressors, including power, wiring, and oil levels.

6.3 Commissioning

7. OPERATION

BMS Operation via BACnet

How to operate the unit using BACnet objects for control and monitoring.

Indoor Fan Configuration

Setting the indoor fan control method, airflow, and speed.

8. MAINTENANCE

Monthly Maintenance Tasks

Routine checks including air filters, drain, and compressor compartment inspection.

Refrigerant Leak Detection Warning

Critical safety warning against using ignition sources for leak detection and handling leaks.

9. TROUBLESHOOTING

APPENDIX I: CONTROLS SET-UP: IP ADDRESS

APPENDIX III: UC8 PROTECTION FUNCTIONS

Discharge Temperature and Superheat Protections

Monitors discharge line temperature and superheat to protect the compressor.

Evaporation;Suction Line and Pressure Protections

Protects against operational extremes based on evaporating/suction line temperatures and pressures.

Indoor Coil Frost Protection

Prevents ice formation on the indoor coil by monitoring evaporating temperature.

UC8 Controller Protections and Timers

COMMISSIONING CHECK LIST

UC8 Monitored Conditions Recording

Procedure to record UC8 monitored conditions for commissioning.

Summary

1. GENERAL

R32 Refrigerant Warning

Alerts users to the mild flammability of R32 refrigerant and necessary precautions.

2. INSTALLATION

Clearances and Service Access

Details necessary space around the unit for proper installation and maintenance access.

4. WIRING

Electrical Requirements and Safety

Outlines electrical connection requirements and essential safety precautions for qualified personnel.

BMS - BACnet Interface

Instructions for connecting and configuring the unit for BACnet communication.

Wiring (Continued)

BMS - Modbus Connection

Guidance on establishing Modbus communication for unit control and monitoring.

6. START-UP PROCEDURE

Pre-Startup Compressor Checks

Essential checks before starting compressors, including power, wiring, and oil levels.

6.3 Commissioning

7. OPERATION

BMS Operation via BACnet

How to operate the unit using BACnet objects for control and monitoring.

Indoor Fan Configuration

Setting the indoor fan control method, airflow, and speed.

8. MAINTENANCE

Monthly Maintenance Tasks

Routine checks including air filters, drain, and compressor compartment inspection.

Refrigerant Leak Detection Warning

Critical safety warning against using ignition sources for leak detection and handling leaks.

9. TROUBLESHOOTING

APPENDIX I: CONTROLS SET-UP: IP ADDRESS

APPENDIX III: UC8 PROTECTION FUNCTIONS

Discharge Temperature and Superheat Protections

Monitors discharge line temperature and superheat to protect the compressor.

Evaporation;Suction Line and Pressure Protections

Protects against operational extremes based on evaporating/suction line temperatures and pressures.

Indoor Coil Frost Protection

Prevents ice formation on the indoor coil by monitoring evaporating temperature.

UC8 Controller Protections and Timers

COMMISSIONING CHECK LIST

UC8 Monitored Conditions Recording

Procedure to record UC8 monitored conditions for commissioning.