EasyManua.ls Logo

Ten-Tec RX-340 - Environmental Conditions

Ten-Tec RX-340
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-9
Signal Handling Characteristics (Preamp Off):
Image Rejection: 90 dB typical, 80 dB minimum (all mixers).
IF Rejection: 90 dB typical, 80 dB minimum (all IFs).
Third order intercept point: 30 dBm typical, 25 dBm minimum (See chart P1-5).
Second order intercept point: +75 dBm, typ, 60 dBm minimum.
Selectivity: 57 bandwidths selectable from 0.1 to 16 kHz. Shape factor better than 1.5:1
(6 to 60 dB).
Bandwidth Selection via Menu:
100 Hz, 120 Hz, 150 Hz, 170 Hz, 200 Hz, 220 Hz, 250 Hz, 300 Hz, 350 Hz, 400 Hz,
450 Hz, 500 Hz, 600 Hz, 700 Hz, 800 Hz, 900 Hz, 1 kHz, 1.1 kHz, 1.2 kHz, 1.3 kHz,
1.4kHz, 1.5 kHz, 1.6 kHz, 1.7 kHz, 1.8 kHz, 1.9 kHz, 2.0 kHz, 2.2 kHz, 2.4 kHz,
2.6 kHz, 2.8 kHz, 3.0 kHz, 3.2 kHz, 3.4 kHz, 3.6 kHz, 3.8 kHz, 4.0 kHz, 4.4 kHz,
4.8 kHz, 5.2 kHz, 5.6 kHz, 6.0 kHz, 6.4 kHz, 6.8 kHz, 7.2 kHz, 7.6 kHz, 8.0 kHz,
8.8 kHz, 9.6 kHz, 10.4 kHz, 11.2 kHz, 12.0 kHz, 12.8 kHz, 13.6 kHz, 14.4 kHz,
15.2 kHz, 16.0k Hz.
Bandwidth Selection via Keypad Entry:
Upon entry, receiver automatically selects the closest filter in the menu of equal or
greater bandwidth.
Fast-Filters:
Fast Filters offer reduced signal latency and degraded shape factors to facilitate
reception of delay-critical digital modes.
Fast-Filter Selection:
All standard menu bandwidths up to 4 kHz are available as Fast Filters.
Fixed Bandwidths:
Bandwidth is fixed at 3.2 kHz in ISB mode.
Minimum available bandwidth is 600 Hz in FM mode, and 4 kHz in SAM mode.
Blocking on tune: <5% THD: -6 dBm input 30% AM 1 kHz.
Blocking off tune: 200 kHz offset. 15 dBm typ. 10 dBm mm for 3 dB desense.
Ultimate Rejection: Greater than 70 dB regardless of filter selected.
Group Delay: No more than .1 ms variation over passband of 300 Hz to 3050 Hz (Notch
OFF).
LO Phase noise: -120 dBc/Hz @ 20 kHz offset typical, -110 dBc/Hz max.
1-3 ENVIRONMENTAL CONDITIONS
Normal Operating:
Temperature: 0 to 50 degrees C (32° to 122°F)
Humidity: Up to 95% Relative Humidity, non-condensing
Altitude: Up to 10,000 feet MSL
Shock: Not applicable
Vibration: Not applicable