EasyManua.ls Logo

Ten-Tec RX-340 - Page 91

Ten-Tec RX-340
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SPECIFICATION TEST SETUP TYP. MIN/MAX
IF REJECTION
(90 dB typ.
80 dB min.)
FIRST IF:
Receive frequency 29.995 MHz, preamp OFF
USB Mode
IF BW 3.2kHz
BFO -1800 Hz
MAGC = 0
Apply 45.456 MHz, -50 dBm
Increase level for 10 dB SINAD.
>10 dBm
-32 dBm MIN
SECOND IF:
Receive frequency 0.500 MHz.
Apply 456 kHz -50 dBm
Increase level for 10 dB SINAD.
>10 dBm
-32 dBm MIN
3
RD
ORDER
INTERCEPT
POINT
(+ 30 dBm typ.
+25 dBm min.)
Configure the Two-Tone test set to produce a low pass-
filtered 16.208 MHz/ 16.308 MHz two-tone output with
each tone at 0 dBm (6 dBm PEP).
Third order products and harmonics at the combiner
output must be less than -80 dBm. Connect the two-tone
output through a 1 dB step attenuator to the receiver RF
input. Receive frequency 16.1072 MHz, preamp OFF Set
MAGC to 65 dB
Note audio output level in dBv. Reduce the two-tone
level by 3 dB and observe a 9 dB drop in audio output.
Remove the two-tone generator and step attenuator.
Connect a 16.1082-MHz generator to RF input. Adjust
generator level for the same audio level noted above.
Generator level should be:
-60 dBm
-50 dBm MAX
Second Order
Intercept Point
(+75 dBm typ.
+60 dBm mm.)
Receive frequency 26.005 MHz, preamp OFF.
MAGC = 0.
Set generator to 22.728 MHz.
Connect sufficient lowpass filtering to generator output to
reduce 2nd harmonic to -100 dBc at -30 dBm output.
Connect filtered generator to RF input.
Adjust generator level for 10 dB SINAD.
Generator level should be: -17 dBm -26 dBm MIN
6-3