DS650E SERVICE MANUAL
[C] r d 4 5 3.0 0 0.0 0 Or Rounding.
[T] 0.0 0 0 0.0 0 0.0 0 Store Tax Rate to EEPROM & return to
Weighing mode.
4.7. Operational Specification List
For The Customer - (1 4 1)
SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
0
Auto Power-off function
(for no key operation & weigh operation)
0000 - Auto power-off disable when scale is not in use
0001 - 3 minute
0010 - 10 minutes
0011 - 30 minutes
0100 - 1 hour
0101 - 3 hours
0110 ~ 1111 - Not used
1
Buzzer
0 - On
1 - Off
Error alarm
0 - On
1 - Off
Currency conversion operation method
00 - Inhibit currency conversion operation
01 - Method 1
10 - Method 2
11 - Not used
2
Decimal point position on currency conversion rate
000 - 7th digit (0.XXXXXX)
001 - 6th digit (X.XXXXX)
010 - 5th digit (XX.XXXX)
011 - 4th digit (XXX.XXX)
100 - 3rd digit (XXXX.XX)
101 - 2nd digit (XXXXX.X)
110 - No decimal point (XXXXXX)
111 - Not used
3 - 11
For Weight & Measure - (1 4 2)
NOTE: It can work only when the SPAN Switch is on (Enable)