DS650E SERVICE MANUAL
4.3. Escape from Maintenance mode
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 0 0 0. 0 0 0.0 0 Weighing mode.
[RE-ZERO] 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Enter 8 7 1 5 while pressing
[RE-ZERO] + [8] [7] [1] [5] C A L 0 0 RE-ZERO.
[T] 0.0 0 0 0. 0 0 0.0 0 Escape to Weighing mode.
[RE-ZERO] 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Enter 8 7 1 5 while pressing
[RE-ZERO] + [8] [7] [1] [5] C A L 0 0 RE-ZERO.
Ensure no weight on platter, [*] - - - - - Calibrating zero point.
:
:
C A L S P
[T] 0.0 0 0 0. 0 0 0.0 0 Escape to Weighing mode.
4.4. Specification Setting
4.4.1. Specification Enter (141)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[RE-ZERO] 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Enter 1 4 1 while depressing
[RE-ZERO] + [1] [4] [1] S P C 0 0 0 0 0 0 0 0 0 0 RE-ZERO.
[+] S P C 0 1 0 0 0 0 0 0 0 0 + key only increase Specification.
[-] S P C 0 0 0 0 0 0 0 0 0 0 - key only decrease Specification.
[0] [1] [0] [1] S P C 0 0 0 0 0 0 0 1 0 1 Only 1 & 0 are enable.
[*] S P C 0 1 0 0 0 0 0 0 0 0 * key to store Specification.
[-] S P C 0 0 0 1 0 1 0 0 0 0
[-] S P C 1 1 1 1 1 1 0 0 0 0
[T] 0.0 0 0 0.0 0 0.0 0 Store SPECS to EEPROM & escape to
Weighing mode.