11
EN
Installaon or removal
Detailed informaon demonstrang the dif-
ferent ways of installing or removing a radi-
ator heang element is available from the
manufacturer or importer (see footnotes at
the end of the manual). Below we list some
basic requirements and principles which
must be followed to ensure long term, reli-
able operaon of the product.
When the heang element is installed hori-
zontally, it must be rotated to such an extent
that the single tube, which houses the temper-
ature sensor, is posioned as low as possible.
Before installaon or rst use:
1. Read the chapter Safety requirements
– Installaon.
2. Fit the heang element using the cor-
rect spanner (size 22).
3. The heang element must be installed
at the boom of the radiator, perpen-
dicular to the radiator pipes, while pre-
serving space for the proper circulaon
of the heang medium.
4 Use a suitable heang medium for ll-
ing the electric radiator, i.e. (water, spe-
cial products based on water and glycol
for use in central heang systems, or oil
which complies with the requirements
of the manufacturer of the radiator and
heang element).
5. DO NOT SWITCH THE HEATING ELEMENT
ON IF IT IS NOT FULLY IMMERSED IN
RADIATOR HEATING MEDIUM (APPLIES
ALSO TO THE FIRST USE)!
6. Make sure an adequate air cushion is pre-
sent to protect against excessive pressure
build up within the electric only radiator
(or leave one of the radiator valves open
in central heang system).
7. When lling the radiator with hot liquid
insure that the liquid temperature does
not exceed 65° C.
8%
(
20° C
)