User manual — ONE
Troubleshoong
Symptom Possible cause Adviced acon
LED diode is not on,
heang element does
not heat
Damaged elec-
tronics
contact Your local Distributor
LED diode pulsing:
WHITE & RED or
WHITE & YELLOW
The radiator is
not warming up
quickly
1. Check and conrm that the heang element's
output is not too low for the size of radiator.
2. (Dual Fuel only) — check the ow of the heated
agent is it owing back into the central heang
system, if this is the case you will need to close one
of the valves (ow or return). In the case of a 'side
connecon' you will need to close the upper valve. If
the problem connues contact Your dealer.
LED
diode
pulsing
WHITE
(mal-
funcon
alert)
TWO
ashes
Low water level
(work in dry con-
dions)
1. May happen once or twice aer switching on - this
is not a malfuncon;
2. If lasts longer - check the lever of heang agent
level
THREE
ashes
Overheang Check and reduce the water temperature in the
central heang system-must not exceed 82 deg
Check and conrm that the heang element's output
does not exceed the recommended output of your
radiator. Turn the heang element o with the ON/
OFF buon and wait for 20 min. If the radiator is sll
hot, disconnect it from its electrical supply - contact
the Distributor.
FOUR
ashes
Temperature sen-
sor damaged
Contact Your local Distributor
FIVE
ashes
The radiator is
not warming up
quickly
1. Check and conrm that the heang element's
output is not too low for the size of radiator.
2. (Dual Fuel only) - check the ow of the heated
agent, is it owing back into the central heang
system, if this is the case you will need to close one
of the valves (ow or return). In the case of a 'side
connecon' you will need to close the upper valve. If
the problem connues contact Your dealer.