3.
TECHNICAL SPECIFICAT
Model
AIC06 AIC08
Advised pool volume
(m
3
)
15~30 20~40
Working air temp ( )
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
6.5 8.0
C.O.P
15.8~7.4 14.7~7.0
C.O.P at 50% speed
11.3 10.6
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
4.8 5.8
C.O.P
8.1~4.8 7.3~4.8
C.O.P at 50% speed
7.0 6.5
Performance Condition:
Air 15°C, Water 26°C, Humidity
Cooling capacity (kW)
3.0 4.0
Rated input
power(kW) at air 15°C
0.12~0.94 0.16~1.2
Rated input current(A)
at air 15°C
0.52~4.1 0.7~5.2
Power supply
Advised water flux
(m³/h)
2~4 2~4
Sound pressure 1m
dB(A)
37.8~47.2 38.8~48.2
Sound pressure 10m
dB(A)
17.8~27.2 18.8~28.2
Water pipe in-out
Spec (mm)
Net Dimension
LxWxH (mm)
961×340×
658
961×340×
658
Net Weight (kg)
43 45
T
he values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration system
running at least 15 hours a day.
Related parameters
are subject to adjustment periodically for technical improvement without further notice. For
details please refer to nameplate.
8
TECHNICAL SPECIFICAT
ION
AIC10 AIC12 AIC13 AIC17 AIC21
25~45 30~55 35~65 40~75 50~95
-7~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
9.8 12.0 13.3 17.3 21.0
15.3~6.9 14.8~5.7 15.4~6.4 15.5~5.9 15.2~5.7
10.7 10.3 10.6 10.8 10.5
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
6.8 8.0 9.4 11.4 14.3
7.7~4.6 7.4~4.3 7.8~4.4 7.8~4.3 7.7~4.2
6.6 6.2 6.5 6.3 6.2
Air 15°C, Water 26°C, Humidity
80%
4.5 5.5 6.2 7.7 10.0
0.21~1.4 0.24~1.8 0.27~2.1 0.3~2.6 0.36~3.3
0.91~6.1 1.04~7.8 1.17~9.1 1.3~11.3 1.57~14.3
230V/1 Ph/50Hz
3~4 4~6 5~7 6.5~8.5 8~10
38.6~49.9 42.1~50.7 41.3~54.0 43.1~53.8 40.9~54.2
18.6~29.9 22.1~30.7 21.3~34.0 23.1~33.8 20.9~34.2
50
961×340×
658
961×340×
658
961×340×
658
961×420×
658
961×420×
758
49 50 52 63 68
he values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration system
are subject to adjustment periodically for technical improvement without further notice. For
AIC28 AIC28T AIC35T
65~120 65~120 90~160
27.3 27.0 35.2
15.3~6.2 15.2~6.2 15.5~5.5
11.0 11.0 10.6
18.0 18.0 24.0
8.1~4.6 7.9~4.5 8.0~4.5
6.7 6.7 7.0
12.1 12.1 16.4
0.53~3.8 0.53~3.9 0.63~5.15
2.3~16.5 0.76~5.6 0.91~7.4
400V/3 Ph/50Hz
10~12 10~12 12~18
43.5~54.9 43.5~54.9 42.6~54.7
23.5~34.9 23.5~34.9 22.6~34.7
1092×420×
958
1092×420×
958
1161×530×
958
90 93 117
he values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration system