EasyManuals Logo

TESTO 410-2 Short Manual

TESTO 410-2
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Specifications 13
Specifications
The testo 410-2 is a flow/humidity/temperature measuring
instrument. It is normally used to measure the air speed at
ventilation outlets. In addition to the simultaneous measurement
of humidity and temperature, climatic conditions can also be
analysed.
Technical data
Measurement data
· Sensors:
Plastic impeller,
Testo humidity sensor,
NTC temperature sensor
· Parameters:
m/s, km/h, fpm, mph, kts, Beaufort,
°C, °F, wind chill, %rH, wet bulb, td
· Measuring ranges:
0.4...20 m/s, 80... 4000 fpm
-10...50 °C, 14...122 °F, 0...100 %rH
· Resolutions:
0.1 m/s, 1 fpm
0.1 °C, 0.1 °F, 0.1 %rH
· Accuracies (Nominal temperatue 22 °C,
±1 Digit):
±(0.2 m/s +2 % of reading),
±(40 fpm +2 % of reading),
±0.5 °C, ±0.9 °F,
±2.5 %rH (5...95%rH)
Long-term stability: ±1 %rF / year
· Measuring rate:
0.5 s, humidity: 1s
Further instrument data
· Protection class: IP10
· Ambient conditions:
-10...50 °C, 14...122 °F
· Storage/transport conditions:
-40...70 °C, -40...158 °F
· Temperature coefficient:
type (k=1) 0.06 %rF / K
· Voltage supply:
2x 1.5 V type AAA
· Battery life:
60 h (without display light)
· Dimensions:
133x46x25mm / 5.2x1.8x1.0 in (inc.
protection cap)
· Weight: 110 g / 3.9 oz (inc. batteries
and protection cap)
Directives, standards and tests
· EC Directive: 2014/30/EC
de
enfres
it
pt
sv
nl
??
??

Other manuals for TESTO 410-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO 410-2 and is the answer not in the manual?

TESTO 410-2 Specifications

General IconGeneral
Measurement ParametersAir velocity, Temperature, Humidity
Air Velocity Range0.4 to 20 m/s
Temperature Range-10 to +50 °C
Humidity Range0 to 100 %RH
Resolution (Air Velocity)0.1 m/s
Resolution (Temperature)0.1 °C
Resolution (Humidity)0.1 %RH
Accuracy (Temperature)±0.5 °C
DisplayLCD
Power Supply2 x AAA batteries
Operating Temperature-10 to +50 °C
Storage Temperature-20 to +70 °C
Dimensions133 x 46 x 25 mm
Unitsm/s, °C, %RH
Measuring PrincipleVane anemometer