EasyManua.ls Logo

TESTO 410-2 - Product description; Product Overview; Initial Setup and Configuration

TESTO 410-2
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product description14
Product description
At a glance
À Protection cap: Park position
Á Impeller
 Humidity/temperature sensor
à Display
Ä Control keys
Å Battery compartment (on rear)
First steps
ã Inserting batteries:
1 To open the battery compartment, push the battery cover
down.
2 Insert batteries (2x 1.5 V type AAA). Observe the polarity!
3 To close the battery compartment, push the battery cover
back on.
ã Basic settings (configuration mode):
Adjustable functions
· Unit of temperature: °C, °F
· Unit of humidity: %, td (dew point), WB (wet bulb)
· Unit of velocity: m/s, km/h, fpm, mph, kts, Beau
· Auto off function: OFF, ON (instrument switches off automatically if no key is
pressed for 10 minutes)
1 When switching the instrument on, press and hold until
and appear on the display (configuration mode).
- The adjustable function is displayed. The current setting
flashes.
2 Press ( ) several times until the desired setting flashes.
3 Press ( ) to confirm the input.
4 Repeat steps 2 and 3 for all functions.
- The instrument changes to measuring mode.

Other manuals for TESTO 410-2

Related product manuals