Page #66 background imageLoading...
Page #66 background image
MSP430F23x
MSP430F24x(1)
MSP430F2410
SLAS547I JUNE 2007REVISED DECEMBER 2012
www.ti.com
Flash Memory
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
V
CC (PGM/ERASE)
Program and erase supply voltage 2.2 3.6 V
f
FTG
Flash timing generator frequency 257 476 kHz
I
PGM
Supply current from V
CC
during program 2.2 V/3.6 V 1 5 mA
I
ERASE
Supply current from V
CC
during erase 2.2 V/3.6 V 1 7 mA
t
CPT
Cumulative program time
(1)
2.2 V/3.6 V 10 ms
t
CMErase
Cumulative mass erase time 2.2 V/3.6 V 20 ms
Program/Erase endurance 10
4
10
5
cycles
t
Retention
Data retention duration T
J
= 25°C 100 years
t
Word
Word or byte program time
(2)
30 t
FTG
t
Block, 0
Block program time for first byte or word
(2)
25 t
FTG
Block program time for each additional
t
Block, 1-63
(2)
18 t
FTG
byte or word
t
Block, End
Block program end-sequence wait time
(2)
6 t
FTG
t
Mass Erase
Mass erase time
(2)
10593 t
FTG
t
Seg Erase
Segment erase time
(2)
4819 t
FTG
(1) The cumulative program time must not be exceeded when writing to a 64-byte flash block. This parameter applies to all programming
methods: individual word/byte write and block write modes.
(2) These values are hardwired into the flash controller's state machine (t
FTG
= 1/f
FTG
).
RAM
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN MAX UNIT
V
(RAMh)
RAM retention supply voltage
(1)
CPU halted 1.6 V
(1) This parameter defines the minimum supply voltage V
CC
when the data in RAM remains unchanged. No program execution should
happen during this supply voltage condition.
JTAG Interface
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
2.2 V 0 5
f
TCK
TCK input frequency See
(1)
MHz
3 V 0 10
R
Internal
Internal pulldown resistance on TEST See
(2)
2.2 V, 3 V 25 60 90 k
(1) f
TCK
may be restricted to meet the timing requirements of the module selected.
(2) TMS, TDI/TCLK, and TCK pullup resistors are implemented in all versions.
JTAG Fuse
(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN MAX UNIT
V
CC(FB)
Supply voltage during fuse-blow condition T
A
= 25°C 2.5 V
V
FB
Voltage level on TEST for fuse blow 6 7 V
I
FB
Supply current into TEST during fuse blow 100 mA
t
FB
Time to blow fuse 1 ms
(1) Once the fuse is blown, no further access to the JTAG/Test, Spy-Bi-Wire, and emulation feature is possible, and JTAG is switched to
bypass mode.
66 Submit Documentation Feedback Copyright © 2007–2012, Texas Instruments Incorporated

Other manuals for Texas Instruments MSP430 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments MSP430 series and is the answer not in the manual?

Texas Instruments MSP430 series Specifications

General IconGeneral
BrandTexas Instruments
ModelMSP430 series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals