System Program Menus Premier 412 & 816 Master User Manual
16 INS141-5
From
Previous Page
Led Key
Off
On
Slow Flash
Fast Flash
N
Text Editing Keys
1
2
3
4
5
6
7
8
.,?!1@”-&
abc2ABC
def3DEF
ghI4GHI
jkl5JKL
mno7MNO
pqrs7PQRS
tuv8TUV
9
0
U
R
wxyz9WXYZ
Space 0 , # *
Move Left/Right
Backspace (delete)
Use keys to enter/edit text.
Then press to accept.y
Engineer
User 00 Text
84
Engineer
^ser 00 Text
Use to select User.
Press
U
n to edit text.
User Text
N
80
Delete User
Armed
Zones
87654321
Ready
Alarm
Service
Enter User Number
??.
Armed
Zones
87654321
Ready
Alarm
Service
Press B
Program User 00
Enter User No.??
Program User 03
Code : ******
Program User 
The Program User option allows the engineer to assign new
users for the alarm system.
Each user is assigned the following attributes:
Access Code
This is a unique 4, 5 or 6 digit code that is assigned to
the user. The system will allow a mixture of different
length Access codes. The Access code must be entered
at a keypad before the user can operate the alarm
system.
User Options 1
See User Options 1 below for details.
User Options 2
See User Options 2 below for details.
User Options 3
See User Options 3 on page 17 for details.
User Options 1 
User Options 1 can be enabled or disabled for a selected
user so that the level of access to the system may be
altered. The following options are available:
Enable for Partition 1
On: The user can access Partition 1.
Off: The user cannot access Partition 1.
Enable for Partition 2
On: The user can access Partition 2.
Off: The user cannot access Partition 2.

Enable for Partition 3 (Premier 816 Only)
On: The user can access Partition 3.
Off: The user cannot access Partition 3.

Enable for Partition 4 (Premier 816 Only)
On: The user can access Partition 4.
Off: The user cannot access Partition 4.

Allow Arming
On: The user can arm the partitions they have been given
access to.
Off: The user cannot arm any partitions.

Allow Bypassing
On: The user can bypass zones in partitions they have
been given access to.
Off: The user cannot bypass zones.

Allow Disarming
On: The user can disarm the partitions they have been
given access to.
Off: The user cannot disarm any partitions.

The Engineer code (User 00) can only disarm the
system if the system was armed with the Engineer
code.

Allow User Functions
On: The user can access the following user functions:
Reset
View Alarm Log
View Service Faults
Enable Chime
Change Own Code
Off: The user cannot access the above user functions.
User Options 2 
User Options 2 can be enabled or disabled for a selected
user so that the level of access to the system may be
altered. The following options are available:

Enable One Time Use Access Code
On: The Access code can only be used once to arm and
disarm the system. After the Access code has been
used to disarm the system it is automatically deleted.
Off: The Access code behaves normally.

Table of Contents