Premier 412 & 816 Master User Manual Operating the Alarm System
INS141-5 9
Changing to another Partition
Normally the remote keypad that you use will be assigned to
a particular partition and therefore the zone and status lights
will indicate information relevant to the assigned partition.
However, you can temporarily switch the remote keypad to a
different partition so that the zone and status lights indicate
the information relevant to the partition that you have
selected. Whilst in this mode you can also use your Access
code to arm/disarm the partition you have selected
(providing you have access to the selected partition).
In order to use the cross partitioning feature, it is
recommend that the system is configured as follows:
Cross partitioning must be enabled.
The user must be assigned to multiple partitions.
The user should be set for “Local Partition Access Only”,
see page 17.
The remote keypads should only be assigned to a
single partition.
To change to another partition, proceed as follows:
AREA ARMED >....
17:35.34 28/04
Enter partition - ,
e.g. Press to select Partition 2.
14
2
Press A
Armed
Zones
87654321
Ready
Alarm
Service
1
2
Premier 816
17:35.38 28/04
The remote keypad will now indicate information
relevant to the selected partition.
Armed
Zones
87654321
Ready
Alarm
Service

After changing to the selected partition, the remote
keypad will only remain in the selected partition for 10
seconds after the last key press. However if an
Access code is entered whilst the remote is in this
mode, the remote keypad will remain in the selected
partition for 1 minute after the last key press.
Bypassing Zones
Manually Bypassing Zones
Bypassing a zone prevents it from causing an alarm.

After manually bypassing a zone, the zone will remain
bypassed until the zone is manually unbypassed.
The Bypass menu will time-out if no key is pressed for
60 seconds.
To manually bypass zones, proceed as follows:
Bypass Zone> 00
*NONE BYPASSED*
Armed
Zones
87654321
Ready
Alarm
Service
YES to Arm?
MENU for Options
The light will flash quickly.Ready
Enter the zone number ,
e.g. Enter to select Zone 2.
??
02
Press B
Enter Access code ????
Armed
Zones
87654321
Ready
Alarm
Service
1
2
3
Bypass Zone> 02
Zone 02 Bypassed
The selected zone is now bypassed. Repeat step 3 to
bypass additional zones.
Armed
Zones
87654321
Ready
Alarm
Service
4
5
Once the selected zones have been bypassed press:
/ to Away arm
to Stay arm
to return to the normal disarmed state
ya
s
N

If the Quick Bypass feature is enabled, you can omit
step 1 from the above procedure.
When one or more zones are bypassed the Ready
light will flash and if the system is fitted with a Premier
RKP16 Plus or Premier LCD/LCDL then the Bypass
light will also illuminate.
Unbypassing Zones
To manually unbypass zones, perform the manual Bypass
procedure on a zone that is already bypassed.
24 hour zones cannot be unbypassed if they are still
violated.
If your installer has enabled the “Reinstate Bypassed
Zones on Disarm” option, all zones will automatically be
unbypassed each time the system is disarmed.
Group Bypass
The Group Bypass feature allows you to bypass a
predefined group of zones. The alarm system has up to four
groups.