Premier Elite 12-W/24-W/48-W Quick Start Guide
INS531-4 9
Zone 009 PIR
69>> 80>> 57 XP
@
If question marks appear it could be because either the system has just been powered
up and information has not been collected yet, or on large systems the information is
not in memory. To populate the display activate the device and the information should
appear.
Device Messages
Zone 001
Not Ricochet
The chosen zone does not have a Ricochet device learned to it.
Zone 009 PIR
Msg ??? mins ago
This display shows the last time the device communicated this represents the
last message and could be a poll, activation or tamper etc.....
Zone 009 PIR
>1hr since msg
This display is a warning showing that the last communication from the device
was over an hour ago.
Zone 009 PIR
No msg recvd yet
This display shows that no message has been received yet, this would
normally be seen on a recently powered up system, wait 15 minutes from
power up before checking the diagnostics information.
Signal Security™
Zone 009 Shock
????
This display shows information relating to signal security on an 8XP-W. 4
windows are available to show information; each window represents two
devices, (Odd & Even device slots). Each window could show any of the
information detailed in the table below.
? No information is available
_ The chosen device cannot “see” either of
the devices
O The chosen device can see the ODD
device(s)
E The chosen device can see the EVEN
device(s)
B
The chosen device can see BOTH
devices
Example
Zone 009 Shock
_OEB
In this example Zone 9 can see the devices as detailed below, use the scroll
key to view information about other devices:-
Display
_ O E B
Device 1 2 3 4 5 6 7 8
Can see
On the 32XP-W there are 16 windows to show information from the 32 devices of the
system; the format is the same.
Device Status
Zone 009 Shock
Status: aaaSpdtt
Secure/OK Active/Fault Type
a A Mag1
a A Mag2/Sho
a A Reed/PIR
s S Poll/Supervision
p P Power/Battery
d D Device
t T Rear
t T Front
Premier Elite SmartKey Messages
User000 Ricochet
Not Ricochet
The chosen user does not have a Premier Elite SmartKey associated with
them.
User002 Ricochet
Not connected
The Premier Elite SmartKey™ is not switched on
User002 Ricochet
Logon Bat OK
Shows the battery is OK and the fob has logged onto the system.
User002 Ricochet
Partarm Bat OK
User002 Ricochet
Disarm Bat OK
User002 Ricochet
Fullarm Bat OK
Shows the different messages displayed when the relevant buttons are
pressed.
User002 Ricochet
Aux? Bat OK
Shows which Aux button has been pressed when in Function Mode.
User002 Ricochet
Panic Bat OK
Shows the Panic function has been activated
YES to erase
unknown keyfobs
Use this option ONLY if the panel has been replaced and not all Premier Elite
SmartKey are recognised by the new panel, or if the error tone is heard when
learning new Premier Elite SmartKey™.
This option DOES NOT remove known Premier Elite SmartKey, use the Delete option
in Setup Users.
Ricochet Diagnostics Menu
Engineer Utils
View Event Log
YES to Select:-
Engineer Utils
y
Zone 009 Shock
Status: aaaSpdtt
?
Zone 009 Shock
->???->???->XP
Zone 009 Shock
??>> ??>> ?? XP
C
Zone 001
Not Ricochet
C
Enter the Zone/Us er
Numbe r to vie w
O
User000 Ricochet
Not Ricochet
Use to scroll
to R ic oc he t Diag
?
User002 Ricochet
Not connected
Turn on
S ma rtKe y
@
Zone 009 Shock
????????????????
C
Zone 009 Shock
>1hr since msg
C
C
User002 Ricochet
->XP
User002 Ricochet
-99>> XP
C
@
User002 Ricochet
Logon Bat OK
C
C
YES to erase
unknown keyfobs
y