    Derrick CastroAug 7, 2025
    What to do if my Texmo Industries Taro Pumps SVSM Water Pump does not run?
    • J
      Jessica EdwardsAug 8, 2025
      If your Texmo Industries Water Pump isn't running, start by checking if there is a power supply to the motor. If the motor coil is burnt, rewind it. Ensure you're operating within the recommended voltage range, as low voltage can be a factor. Also, check if the motor starter overload has tripped and reset it. If it trips again, check the voltage. The pump may be jammed, so dismantle it and clear any jammed parts. Replace the fuse if it has blown, and tighten any loose electrical connections. If the pump has been idle for a long time, ensure free shaft rotation by running it for a few minutes every other day.
  • M
    mfloydAug 13, 2025
    Why is my Texmo Industries Taro Pumps SVSM Water Pump leaking excessively?
    • K
      Kyle CampbellAug 13, 2025
      If your Texmo Industries Water Pump is leaking excessively, the gaskets or O-rings may be damaged, so check and replace them. Also, examine the pipeline for damage and replace any damaged sections.
  • A
    ahoffmanAug 17, 2025
    Why Texmo Industries Water Pump has less discharge?
    • N
      natasha67Aug 17, 2025
      If your Texmo Industries Water Pump has less discharge, start by checking the supply voltage and ensure it's operating within the recommended range. The wrong direction of rotation could also be the cause. Ensure the delivery head is within the specified value. Also, if a smaller pipe size is used compared to nameplate recommendations, replace it with the suggested pipe size.
  • S
    Sandra MitchellAug 23, 2025
    How to fix low total head developed in Texmo Industries Taro Pumps SVSM?
    • S
      Steve PachecoAug 23, 2025
      To address low total head in your Texmo Industries Water Pump, consider these points. Abrasive wear of pump hydraulics might be the cause if you're operating in water with higher sand content or corrosiveness, in this case change the worn-out pump parts. If the pump is running at low voltage, wait for the voltage to increase or contact your local EB representative. Low system head can also lead to higher discharge, so throttle the discharge to adjust.
  • Y
    ypollardAug 28, 2025
    Why Texmo Industries Taro Pumps SVSM runs rough and noisy?
    • M
      mark51Aug 28, 2025
      If your Texmo Industries Water Pump runs rough and noisy, it may be due to dry running of the pump. Keep the pump idle for some time or reduce the discharge by throttling. A bent shaft could also be the issue, so replace the shaft if necessary. Excessive wear and tear can also cause this problem, so service the pump, replacing the worn-out parts.
  • D
    Deanna RodriguezSep 2, 2025
    What to do if Texmo Industries Taro Pumps SVSM has less discharge?
    • J
      Jose JosephSep 2, 2025
      If your Texmo Industries Water Pump has less discharge, start by cleaning the discharge pipe if it's internally coated with depositions. Check the impellers for any foreign bodies and remove them. Also, inspect the valve in the discharge pipe to ensure it is not partly closed or blocked; clean or replace the valve if necessary. Check and clean the NRV and replace it if necessary. Finally, check the pipework for any leakage and repair or replace the piping.

Summary

Pump Information and Series

Key Specifications and Features

Standard Specifications Table

Details technical specifications like power, motor type, voltage, frequency, speed, duty, temperature, and impeller type.

Core Product Features

Highlights features such as wide voltage band, water-lubricated bearings, balanced rotors, and efficient cooling.

Pre-Installation Requirements

Safety and Handling Notes

Provides crucial notes, warnings, and cautions regarding product inspection, lifting, installation, power supply, earthing, and operation.

Installation Procedure

Installation Precautions and Warnings

Highlights supply voltage, water temperature, and general warnings about malfunction and electrical shock.

Pre-Installation Steps

Details steps like filling motor with water, measuring insulation resistance, checking contacts, and connecting cables.

SVSM Horizontal Mounting

Motor Cable Joint Waterproofing

Electrical Safety Warning for Cable Work

Warns about hazardous voltage and the need to disconnect power before working on equipment.

Waterproofing the Supply Cable Joint

Instructions for waterproofing the submersible motor cable to supply cable joint for underwater applications.

Cable Jointing and Insulation Guide

Step-by-step guide for soldering conductors and insulating cable joints using rubber insulation and PVC tape.

Checking Motor Rotation Direction

Electrical Wiring and Earthing

Connecting Power Supply

Basic Troubleshooting

Troubleshooting Safety Precautions

Emphasizes disconnecting power before inspecting the pump and seeking professional help for servicing.

Common Faults and Suggested Actions

Lists common faults like 'Pump does not run' or 'Less discharge' with their possible causes and suggested actions.

Preventive Maintenance Checks

Dos and Donts for Operation

Installation and Operation Guidelines

Provides essential 'Do's' and 'Don'ts' for installation, earthing, mounting, piping, electrical connections, and operation to ensure safety and performance.

Important Safety Instructions

Critical Safety Instructions for Personnel

Stresses that only qualified personnel should perform inspection, maintenance, and repairs, and to contact the dealer for non-functioning products.

Storage and Handling Guidelines

Texmo Industries Taro Pumps SVSM Series Specifications

General IconGeneral
BrandTexmo Industries
ModelTaro Pumps SVSM Series
CategoryWater Pump
LanguageEnglish

Related product manuals