Textron Bell 412 - 5-25. EACH 1000 HOURS OF COMPONENT OPERATION

Textron Bell 412
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BHT-412-MM-2
5-00-00
Page 138 Rev. 26 01 JUN 2018
Export Classification C, ECCN EAR99
SPECIAL INSPECTIONS
5-25. EACH 1000 HOURS OF COMPONENT OPERATION
DATA REFERENCE INSPECTION TASK DESCRIPTION
INITIAL
MECH OTHER
Accomplish each 1000 hours of component
operation.
Chapter 29 HYDRAULIC ACCUMULATORS
TB 412-17-240
The following inspection is not required if the intent of
the TB 412-17-240 is accomplished.
The following procedure only applies to helicopters
S/N 33001 through 33213 and 36001 through 36627.
1. Remove hydraulic accumulators.
BHT-412-CR&O 2. Disassemble, clean, and visually inspect for corrosion and
damage.
3. Replace any unserviceable parts.
4. Reassemble hydraulic accumulators.
Chapter 29 5. Install hydraulic accumulators.

Table of Contents