What does error P1 mean on a TGM Air Conditioner?
- QqjohnsonAug 17, 2025
If your TGM Air Conditioner displays error code P1, it indicates high pressure protection has been activated.
What does error P1 mean on a TGM Air Conditioner?
If your TGM Air Conditioner displays error code P1, it indicates high pressure protection has been activated.
What does error P2 mean on a TGM T16CU16VT36S?
If your TGM Air Conditioner displays error code P2, it indicates low pressure protection has been activated.
What does error P3 mean on a TGM Air Conditioner?
If your TGM Air Conditioner displays error code P3, it means that DC over current protection is active.
What does error E9 mean on a TGM T16CU16VT36S Air Conditioner?
If your TGM Air Conditioner displays error code E9, it indicates AC under voltage protection.
What does error P4 mean on a TGM T16CU16VT36S Air Conditioner?
If your TGM Air Conditioner displays error code P4, it indicates that the T5 discharge temperature is abnormal.
What does error E4 mean on a TGM Air Conditioner?
If your TGM Air Conditioner displays error code E4, it indicates a T4 outdoor ambient temperature sensor error.
What does error E5 mean on a TGM Air Conditioner?
If your TGM Air Conditioner displays error code E5, it indicates a T5 discharge temperature sensor error.
What does error E6 mean on a TGM T16CU16VT36S?
If your TGM Air Conditioner displays error code E6, it indicates a T3 condenser temperature sensor error.
What does error P6 mean on a TGM T16CU16VT36S?
If your TGM Air Conditioner displays error code P6, it indicates that the IPM module protection has been activated.
What does error E10 mean on a TGM T16CU16VT36S?
If your TGM Air Conditioner displays error code E10, it indicates an EEPROM error.
Lists model names, dimensions, and power supply for indoor and outdoor units.
Visuals of indoor and outdoor units, showing cassette, floor-ceiling, and top-discharge types.
Highlights key features like capacity, compressor brand, coil types, and refrigerant.
Detailed technical specifications for the outdoor unit, including dimensions, power, and refrigerant.
Provides physical dimensions (A, B, C) and refrigerant pipe connection sizes for models.
Illustrates required clearance around the outdoor unit for installation and maintenance.
Electrical wiring diagram for the outdoor unit, showing connections for various components.
Details electrical specifications like voltage, frequency, and motor output for the outdoor unit.
Specifies the operational temperature ranges for cooling mode for the outdoor unit.
Lists noise levels (dB(A)) for different outdoor unit models.
A detailed breakdown of outdoor unit components with part numbers and quantities.
Lists fault codes, their descriptions, and potential solutions for the outdoor unit.
Features and specifications of the round-way cassette indoor unit.
Features of the floor & ceiling indoor unit, including installation flexibility.
Guidelines for connecting pipes, including tightening torque and flare dimensions.
Procedures for vacuum drying the system and checking for leaks.
Instructions for calculating and adding refrigerant based on pipe length and diameter.
Details on insulating refrigerant and drainage pipes for optimal performance.
Steps for conducting test operations to ensure proper functioning of the installed unit.
| Brand | TGM |
|---|---|
| Model | T16CU16VT36S |
| Category | Air Conditioner |
| Language | English |