Page #26 background image
20
Chapter 3: System Administration
S.M.A.R.T. Information
Item Description
Tray Number Tray the hard disk is installed in.
Model Model name of the installed hard disk.
Power ON Hours
Count of hours in power-on state. The raw value of this attribute shows total count of hours (or min-
utes, or seconds, depending on manufacturer) in power-on state.
Temperature Celsius The current temperature of the hard disk in degrees Celsius.
Reallocated Sector Count
Count of reallocated sectors. When the hard drive finds a read/write/verification error, it marks this sec-
tor as "reallocated" and transfers data to a special reserved area (spare area).
This process is also known as remapping and "reallocated" sectors are called remaps. This is why, on a
modern hard disks, you cannot see "bad blocks" while testing the surface - all bad blocks are hidden in
reallocated sectors. However, the more sectors that are reallocated, the more a decrease (up to 10% or
more) can be noticed in disk read/write speeds.
Current Pending Sector
Current count of unstable sectors (waiting for remapping). The raw value of this attribute indicates the
total number of sectors waiting for remapping. Later, when some of these sectors are read successfully,
the value is decreased. If errors still occur when reading sectors, the hard drive will try to restore the
data, transfer it to the reserved disk area (spare area), and mark this sector as remapped. If this attribute
value remains at zero, it indicates that the quality of the corresponding surface area is low.
Test Type Set short or long time to test.
Test Result Result of the test.
Test Time Total time of the test.
Bad Block Scan
On the Disk Information screen, select a disk then click on Detect Bad Block to perform bad block
scan of the associated disk. The result is only for reference and the system will not take any action
from its results.
The bad block scan can be terminated by clicking on Stop Detect Bad Block.
RAID Information3.4.2
From the Storage menu, choose the RAID Management item and the RAID Management screen ap-
pears.
This screen lists the RAID volumes currently residing in the Thecus IP storage. From this screen, you
can get information about the status of your RAID volumes, as well as the capacities allocated for
data.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N2310 series and is the answer not in the manual?

Thecus N2310 series Specifications

General IconGeneral
Memory512MB DDR3
RAID SupportRAID 0, 1, JBOD
Drive Bays2 x 3.5" SATA HDD
Network Interface1 x Gigabit Ethernet
USB Ports2 x USB 3.0
Network ProtocolsCIFS/SMB, AFP, NFS, FTP, HTTP
Power Consumption5W (Standby)
Operating SystemThecusOS