English 3
High Altitude:
For safe LP conversion of an appliance for use at higher
elevations, consult the local gas company for their
recommendations for correct orifice sizes and any other
necessary adjustments that will provide proper gas
combustion at high altitudes.
Step 1: Accessing the Gas
Regulator and Burner Orifices
NOTICE:
After the replacement of each orifice, and before
re-assembly of the burner, perform a brief gas leakage
check of the orifice and associated fittings, per the
“Check for Gas Leaks” section of these instructions.
1. Disconnect all electrical power at the main circuit
breaker or fuse box.
2. Shut off the gas supply to the range by closing the
manual shut-off valve.
3. Remove the cooking grates.
Appliance
Model
Number
Star
®
Burners
Jet Orifice
POWERBOOST
TM
Jet Orifice
THERMADOR PRO GRAND
®
Dual-Fuel Ranges:
PRD364JDG* 3 each - 1.15mm 1 each - 1.25mm
PRD366JGC 5 each - 1.15mm 1 each - 1.25mm
PRD486JDG* 5 each - 1.15mm 1 each - 1.25mm
PRD48JDSG* 5 each - 1.15mm 1 each - 1.25mm
NOTES:
* Model numbers with letter “D” have an Electric
Griddle, which does not require conversion to gas.
Table 2: LP Orifice Conversion Chart

Table of Contents

Other manuals for Thermador PRD364JDGU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermador PRD364JDGU and is the answer not in the manual?

Thermador PRD364JDGU Specifications

General IconGeneral
BrandThermador
ModelPRD364JDGU
CategoryOven
LanguageEnglish

Related product manuals