Menu selection Meaning Factory setting
RETURN LINE Shows the actual return temperature. The stop temperature, MAX RETURN is within
brackets.
-
BUFFER TANK Indicates the buffer tank temperature, if activated. -
HOT WATER Indicates actual hot water temperature, if activated. -
INTEGRAL Shows the actual calculated value for integral. -
BRINE IN Shows the actual temperature for brine in. -
BRINE OUT Shows the actual temperature for brine out. -
POOL Only appears if POOL is selected. Shows the actual pool temperature. The set pool tem-
perature is shown in brackets.
-
COOLING Indicates temperature.
SHUNT GROUP Only appears if SHUNT GROUP is selected. Shows the actual supply temperature. The cal-
culated supply temperature to the shunt group is within brackets.
-
2ND HEAT CIR. Shows the temperature of the second heating circuit if installed by the buffer tank sys-
tem.
CURRENT Only appears if CURRENT LIMITER is selected. Shows the actual current consumption. The
set value for MAX CURRENT is shown in brackets.
-
8.5 Sub-menu OPERAT.TIME
Menu selection Meaning Factory setting
HEAT PUMP Compressor operating time for both heating and hot water production. -
AUX. HEAT 1 OPERAT. TIME AUX. HEATER 1. -
AUX. HEAT 2 OPERAT. TIME AUX. HEATER 2.
AUX. HEAT 3 OPERAT. TIME AUX. HEATER 3.
HOT WATER Operating time for hot water with compressor. -
COOLING Operating time cooling.
ACT COOLING Operating time active cooling.
8.6 Sub-menu DEFROST
Menu selection Meaning Factory setting
DEFROSTS Total number of defrosts carried out. -
BETW. 2 DEFR The operating time of the compressor in minutes between the two last defrosts. -
TIME LAST DEFR The operating time of the compressor in minutes since last defrost. -
FAN H OFF AT High speed is deactivated at this temperature and low speed is activated. 12°C(range:
10°C / 20°C)
DEFROST CURVE Used to change the angle of the defrost curve using + or– (Change the start temperature
for defrost).
-10°C(range:
-13°C / -7°C)
MANUAL DEFR Used to perform a manual defrost. Started using + or -. 0(range: 0 / 1)
8.7 Sub-menu LANGUAGE
Menu selection
SVENSKA
ENGLISH
DEUTSCH
NEDERLANDS
FRANÇAIS
Installation Guide Domestic heat pumps
Thermia Värmepumpar VMGFP202
49

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermia Diplomat Duo Optimum G3 and is the answer not in the manual?

Thermia Diplomat Duo Optimum G3 Specifications

General IconGeneral
BrandThermia
ModelDiplomat Duo Optimum G3
CategoryHeat Pump
LanguageEnglish

Related product manuals