4 Transport, unpacking and setting-up
4.1 Transporting the heat pump
Caution During transportation and lifting of the entire heat pump, the front
panel must always be in place as it locks the other panels in position.
Caution The heat pump must always be transported and stored upright in a
dry environment. Secure the heat pump so that it cannot tip over dur-
ing transportation.
Caution The heat pump must not be tilted more than 45° in any direction.
If the heat pump is tilted more, it may become seriously damaged as
the oil in the compressor can run out in the pressure pipe and there-
fore prevent normal function.
4.2 Unpacking
1. Check that there is no transport damage.
2. Check the tilt indicator on the packaging.
3. Remove the packaging.
4.2.1
Delivery check
Check that the delivery contains the following components:
Component
Quantity
Safety valve 9 bar ½" 1
Safety valve 3 bar ½'' 1
Outdoor sensor 1
Expansion and bleed tank or Expansion vessel with manometer 1
Rubber bellows for 22-28 mm hole 5
Flexible hose 2
Filling device 1
Dirt strainer with shut off valve 1
Manual holder 1
Silicone hose (Duo only)
Diplomat Duo Inverter
1
4.3 Setting-up the heat pump
Installation Guide Diplomat Inverter/Diplomat Duo Inverter
Thermia Värmepumpar VMJSC302
11