2.3.5 Scrapping
Caution When the heat pump is to be scrapped the refrigerant must be extrac-
ted for disposal. Local rules and regulations related to the disposal of
refrigerant must be followed.
2.4 Electrical connection
Warning Hazardous electrical voltage! The terminal blocks are live and can
cause death through electric shock. All power supplies must be isola-
ted before electrical installation is started. The heat pump is connec-
ted internally at the factory, for this reason electrical installation con-
sists primarily of the connection of the power supply.
Caution Electrical installation may only be carried out by an authorized electri-
cian and must follow applicable local and national regulations.
Caution The electrical installation must be carried out using permanently rout-
ed cables and must follow applicable local and national regulations. It
must be possible to isolate the power supply using an all-pole circuit
breaker with a minimum contact gap of 3 mm.
Installation Guide Diplomat Inverter/Diplomat Duo Inverter
VMJSC302 Thermia Värmepumpar
8