Specifications
152
Electrical Standby (SmartPower Units Only)
NOTE: A transformer is used to convert 460 Vac to 230 Vac in units configured to use electric standby
input voltage of 460 Vac.
Electric Motor and Overload Relay
Voltage/Phase/Frequency Horsepower Kilowatts rpm Full Load
(amps)
Overload Relay
Setting (amps)
230/3/60 12.0 9.0 1760 31.2 34
460/3/60 12.0 9.0 1760 15.6 20
460/3/60 19.0 14.2 3500 21.7 32