NAPCO Series 8000DH
CO2 Incubator
Direct Heat with Sterilization Cycle
Operating and Maintenance Manual 7003584 Rev. 9
Question and Answer IconNeed help?

Do you have a question about the Thermo Scientific 3598 and is the answer not in the manual?

Thermo Scientific 3598 Specifications

General IconGeneral
BrandThermo Scientific
Model3598
CategoryAccessories
LanguageEnglish

Summary

Installation and Start-Up

Keypad Operation

Describes the incubator's four basic modes: Run, Setpoints, Calibration, and Configuration.

Installing the Incubator

Provides instructions for proper placement, clearance, and lifting of the incubator unit.

Electrical Power Connection

Covers connecting the incubator to a grounded, dedicated electrical circuit.

Connecting the CO2 Gas Supply

Details connecting the CO2 gas supply, regulator requirements, and purity.

Incubator Start-Up

Outlines steps to enter system setpoints after installation and connection.

Setting the Operating Temperature

Guides on how to set the desired operating temperature setpoint.

Setting the Overtemp Setpoint

Explains how to set the overtemperature safety setpoint for protection.

Setting the CO2 Setpoint

Details how to set the desired CO2 concentration setpoint for the incubator.

Calibration

Thermal Conductivity CO2 System

Explains calibration for T/C CO2 sensors, considering atmospheric factors.

Infrared CO2 System

Details calibration for IR CO2 sensors, noting temperature change effects.

Configuration

Set Low Temp Alarm Limit (tracking alarm)

Defines the deviation from setpoint that triggers a low temperature alarm.

Set Low CO2 Alarm Limit (tracking alarm)

Sets the deviation from setpoint for a low CO2 alarm.

Set High CO2 Alarm Limit (tracking alarm)

Sets the deviation from setpoint for a high CO2 alarm.

Alarms

Temp Controller Failure TMP CNTR ERR

Describes the alarm for a failure in the temperature control system.

Sensor Fault Alarms

Covers alarms indicating issues with any of the incubator's sensors.

Routine Maintenance

Sterilization Cycle

Provides information and procedures for performing the high-temperature sterilization cycle.

Specifications

Temperature

Specifies temperature control, setpoint, range, uniformity, and display.

Warranty Information