Thermo Scientific
TRACE 1310 Auxiliary
Oven
Instruction Manual
Additional Section of the TRACE 1300/1310 Gas
Chromatographs Hardware Manual & User Guide
PN 31715011 Revision D January 2016
Home

Table of Contents

Other manuals for Thermo Scientific TRACE 1310

Question and Answer IconNeed help?

Do you have a question about the Thermo Scientific TRACE 1310 and is the answer not in the manual?

Thermo Scientific TRACE 1310 Specifications

General IconGeneral
BrandThermo Scientific
ModelTRACE 1310
CategoryLaboratory Equipment
LanguageEnglish

Summary

Chapter 1 Site Preparation

Introduction

Describes the TRACE 1310 Auxiliary Oven's purpose and placement.

Entrance Requirements

Details necessary clearances and pathways for equipment delivery.

Workbench & Space Requirements

Specifies workspace dimensions, load capacity, and clearances.

Lighting Requirements

Outlines necessary illumination for the work area.

Power Requirements

Lists electrical specifications and needs for the system.

LAN Network Requirements

Defines network connectivity needs for data systems.

Environment Requirements

Specifies operational conditions like temperature, humidity, and pollution.

Gas Equipment Requirements

Details necessary ultra-high purity GC gas supplies.

Receiving Instruments

Provides guidelines for inspecting and handling delivered equipment.

What Happens Next?

Outlines post-delivery steps and installation scheduling.

Chapter 2 TRACE 1310 Auxiliary Oven Overview

Front View

Describes components and features visible on the front panel.

Top View

Details components located on the top surface of the oven.

Back View

Identifies ports, fans, and connectors on the rear panel.

Right View

Shows components on the right side, including the main oven.

Left View

Describes the left side and its connection to the main GC.

Internal View

Explains the interior layout, divided into heated/unheated compartments.

The Heated Compartment

Details main oven, optional secondary oven, and methanizer.

The Unheated Compartment

Describes valve configurations within the unheated section.

Main Oven

Focuses on the primary oven compartment and its valve capacity.

Label Location on the Instrument

Illustrates the placement of various instrument labels.

Tools Needed

Lists required tools for component installation.

Chapter 3 Components Installation

Installing the Valves

General guide for installing and configuring valves.

Installing Valves and Fittings into the Main Oven

Procedures for installing valves in the heated section.

Bulkhead Connectors for High Temperature

Instructions for installing high-temperature connectors.

Installing the Rotary Valves into the Main Oven

Procedure for fitting rotary valves into the main oven.

Installing the Diaphragm Valves in The Main Oven

Steps for installing diaphragm valves in the main oven.

Installing Valves and Fittings in the Unheated Compartment

Instructions for components in the unheated section.

Installing an Unheated Rotary Valve into the Unheated Compartment

Procedure for unheated rotary valve installation.

Installing an Unheated Diaphragm Valve into the Unheated Compartment

Steps for unheated diaphragm valve installation.

Installing the Auxiliary Gas Modules

Instructions for installing gas modules.

Special Use of the Auxiliary Gas Module for Controlling the Split Flow

Details on using gas modules for split flow control.

Installing the Auxiliary Detectors Assembly

Guide for installing auxiliary detector components.

Installing the Secondary Oven Assembly

Instructions for mounting the secondary oven.

Installing the Methanizer Assembly

Procedure for installing the methanizer unit.

Installing a Heated Sample Transfer Line

Steps for connecting the heated transfer line.

Wiring the TRACE 1310 Auxiliary Oven to the GC

Instructions for electrical connections between units.

Coupling the TRACE 1310 Auxiliary Oven to the GC

Procedures for physically connecting the oven to the GC.

Chapter 4 Operation

Operating Through the GC Touch Screen

Guide for configuring and operating via the GC touch interface.

Operating Through the CDS

Instructions for operation using Chromatography Data Systems.

Chapter 5 Maintenance & Troubleshooting

Read Me First

Important initial information and warnings for maintenance.

Maintenance Supplies and Tools

Lists necessary items for routine upkeep.

Powering On the TRACE 1310 Auxiliary Oven

Steps for safely starting the instrument.

Shutting Down the TRACE 1310 Auxiliary Oven

Procedures for powering off the system.

Cleaning the Instrument Externally

Guidelines for exterior cleaning.

Replacing the Column into the Secondary Oven

Instructions for changing the column.

Maintaining the Methanizer

Procedures for methanizer upkeep.

Troubleshooting

Guidance for resolving common operational issues.

Leak Testing

Method for detecting leaks in the system.

Valve Switching

Addresses issues with valve operation.

Valve Plumbing

Verifies correct valve and system connections.

Methanizer Analytical Troubleshooting

Diagnoses and resolves methanizer issues.

Chapter 6 Ordering Parts