17
Technical Manual
© 2006 by Thermoplan, Subject to change
Tiger REV-8
SECTION 3
In this menu the several machine maintenance parameter can be set.
By pressing the enter key you access the menu.
7 Mach Maintenance
7-1 Time Date
hh:mm:ss dd-mm-yy
14:40:15 19-06-07
In menu 7-1 you can set the time and date. Use the Plus-/Minus levers to adjust the values. Press the
enter key to
step to the next value.
In menu 7-2 you can set the desired language with the Plus-/Minus levers.
Language: German / French / English
7-2 Language
English
7-3 Temp. Unit
°C
In menu 7-3 you can set the desired Temperatur unit °C (Celsius) or °F (Farenheit) with the Plus-/Minus levers.
Menu 7
7-5 Grinder Capcty ->
03.50 mm/sec
In menu 7-5 you can set the grinder capacity of grinder 1.
7-6 <- Grinder Capcty
03.00 mm/sec
In menu 7-6 you can set the grinder capacity of grinder 2.
7-7 Display Contrast
017
In menu 7-7 you can adjust the Display contrast.
7-10 Service Date
dd-mm-yy
22-06-07
7-13 Filter Wat. Date
dd-mm-yy
22-06-07
7-9 Serv Intervall
030000 cyclus
In menu 7-9 you can set the service interval with the Plus-/Minus levers.
In menu 7-11 you can set the coffee quantity with the Plus-/Minus levers. This menu is used, when a customer has
only an amount of coffee to use (e.g. leased machines).
7-11 Coffee Qnty
010.000 kg
In menu 7-12 you can set the water lter with the Plus-/Minus levers.
7-12 Filter Water
03000 ltr
in menu 7-10 the date shows, when the next service must take place.
In menu 7-13 the date shows, until when at the latest the lter must be changed.