Problem encountered Check to be made
The radiator does not
heat enough
Increase the Comfort set temperature.
If the setting is at the maximum, make the following checks:
-Check if there is another heating source in the room
- Make sure that your radiator is only heating the room (door
closed).
- Have the radiator power supply voltage checked.
- Check if the power of your radiator is appropriate for the
size of your room (we recommend about 100W/m
2
for a
ceiling height of 2.50 m).
Traces of dirt collect
on the wall around the
radiator
Dirt is caused by poor quality of ambient air. In this case, it
is recommended that good aeration of the room (ventilation,
air inlet, etc.), and cleanliness of the air should be checked,
and do not smoke indoors. This dirt does not justify
replacement of the radiator under guarantee.
The heating pictogram
is displayed on the
screen when the
radiator is in ECO mode
This operation is normal. The radiator can warm up so as to
maintain an Eco temperature.
For radiators equipped with a programming system or controlled through the pilot wire.
The radiator does
not follow external
programming controls
Make sure that the programming control unit is used
correctly (see user’s instructions), that the programming unit
is properly engaged in its housing and that it is functioning
normally (check the condition of the batteries, fuse, etc. ).
Make sure that your radiator is in Program mode and that
the external « centralised » program is assigned to the
required day of the week.
The radiator surface is
very hot
It is normal that the radiator should be hot when it is in
operation, but the maximum surface temperature is limited
in accordance with the NF Electricity performance standard.
However, if you think that your radiator is still too hot, make
sure that the power is appropriate for the surface area of
your room (we recommend 100W / m² for a ceiling height
of 2.50 m) and that the radiator is not placed in a draft that
would disturb its regulation.
There is a signicant
difference between the
ambient temperature
in the room and
the equipment set
temperature
After 6h stabilisation, you can recalibrate your radiator by
doing a long press (3 sec) on
and and wait until «
OFFSET » is displayed.
Set the observed temperature difference by pressing the +
or - button and then conrm by pressing the
button.
Example: If the ambient temperature is 20°C and the set
temperature is 18°C, add +2° to the «OFFSET » value.
Equateur2_1880-1585_interieur.indd 90 18/06/12 06:23

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermor R4GHD2-Mk22 and is the answer not in the manual?

Thermor R4GHD2-Mk22 Specifications

General IconGeneral
BrandThermor
ModelR4GHD2-Mk22
CategoryHeater
LanguageEnglish

Related product manuals