TS 970
AUTOMATIC TRANSFER SWITCH
WITH TSC 900 CONTROLLER
INSTALLATION, OPERATING & SERVICE
MANUAL
4916 - 275th Street, Langley, BC, Canada V4W 0A3 · Telephone (604) 888-0110
Email: info@thomsonps.com · www.thomsonps.com

Questions and Answers

  • D
    Darlene GrahamNov 3, 2025
    What to do if Thomson Power Systems TS 970 will not re-transfer to utility source upon restoration?
    • R
      robert43Nov 3, 2025
      If the Thomson Power Systems Switch won't re-transfer to the utility source after it's restored, consider these potential causes: * The Utility Return Time delay period in TSC 900 hasn't expired yet, so verify the TSC 900 time delay setting. * A Load Test mode may be active, so check the TSC 900 GHC Home Page status indicators. * An Exercise Test mode could be activated by the TSC 900 scheduler; check the TSC 900 GHC Scheduler page. * The utility supply might not be operating at the correct voltage or frequency levels; verify the nominal levels and compare them to the TSC 900 settings. * The TSC 900 may have incorrect utility voltage or frequency settings; re-program the TSC 900 with the correct settings. * The Utility Phase Rotation might not match the Generator supply; check...
  • C
    Christopher DavisNov 13, 2025
    Why Thomson Power Systems Switch transfer to generator source without a power failure in the utility source?
    • J
      Jamie WalshNov 14, 2025
      The Thomson Power Systems Switch might transfer to the generator source even without a utility power failure due to several reasons: * A Load Test mode has been activated either locally or remotely. You should check the TSC 900 GHC Home Page status indicators. * An Exercise Test mode has been activated by the TSC 900 scheduler. In this case, check the TSC 900 GHC Scheduler page. * The utility supply is not operating at the correct voltage or frequency levels. Verify the correct nominal levels and compare them to the TSC 900 settings for voltage, phase balance, and frequency. * The TSC 900 has incorrect utility voltage or frequency settings for the ATS. Re-program the TSC 900 with the correct settings. * The utility power switching device has tripped open due to an over current c...
  • L
    Lisa BryantNov 23, 2025
    What to do if Thomson Power Systems TS 970 will not transfer to generator source upon failure of utility source?
    • A
      Andrew BoydNov 23, 2025
      If your Thomson Power Systems Switch fails to transfer to the generator source when the utility source fails, here are some potential causes: * The warm-up time delay function hasn't timed out yet. You should verify the TSC 900 timer setting. * The generator set output circuit breaker feeding the ATS is open. Ensure you close the generator set output circuit breaker. * The generator supply isn't operating at the correct voltage or frequency levels. Check the nominal levels and compare them to the TSC 900 settings for voltage, phase balance, and frequency. * The TSC 900 has incorrect generator voltage or frequency settings for the ATS. Re-program the TSC 900 with the correct settings. * The generator phase rotation may not match the utility supply, especially during the first-tim...

Summary

Notes to Installer

General Description

TSC 900 ATS Controller

Description of the TSC 900 microprocessor-based controller with GHC and SCU.

Power Contactor ATS

Details on the two types of power contactors used based on amperage size and features.

Product Model Code

Explanation of the 21-digit product code structure and definitions.

Typical Commissioning Procedures

Procedures for commissioning the ATS by qualified personnel.

Automatic Sequence of Operation

Standard ATS - Open Transition

Step-by-step explanation of the open transition automatic sequence.

General Notes on Servicing Power Contactor ATS

Equipment Inspection

Key checks for maintaining mechanical and electrical integrity during service.

Recommended Maintenance

Procedures and precautions for maintaining the automatic transfer switch.

ATS Manual Operating Instructions

100 A - 400 A Power Contactor ATS Manual Operation

Instructions for manual operation of 100A-400A ATS using supplied tools.

7.1.1. Manual Closing to Utility Position (Side A)

Step-by-step procedure to manually close to the utility position.

Ground Fault Site Test Requirements

Troubleshooting

General Troubleshooting

Common malfunctions, probable causes, and corrective actions for ATS.

Replacement Parts

Appendix A: Typical TS 970 ATS Commissioning Procedures

Appendix B: TS 970 System Voltage Change Procedure

Appendix C: Seismic Certificate