8.
10.
Record/Playback
Head
Replacement
Should
a
loss
of
high-frequency
signals
be
noted
in
the
reproduced
program,
the
calibration
and
test
pro-
cedures
of
Sections
9,
10
and
13
should
first
be
conducted.
!f
specified
performance
cannot
be
attained,
replace
the
record/playback
head
(3062335,
Fig.
9)
as
follows:
a)
Unsolder
the
shielded
cables
from
the
terminal
board
of
the
head.
b)
Remove
the
left-hand
mounting
screw
and
loosen
the
right-hand
screw.
c)
Remove
the
head
and
mount
a
replacement
head.
The
left-hand
screw
is
to
be
tightened
completely,
while
the
right-hand
screw
should
be
turned
until
the
head
is
paralle!
to
the
mounting
plate
(chassis).
d)
Solder
the
shielded
cabies
onto
the
terminal
board
of
the
head.
e)
Perform
the
adjustments
in
Sections
9
and
11
-
13.
Azimuth
Adjustment
The
azimuth
(head
alignment)
adjustment
can
be
performed
without
removing
the
front
panel
assembly
through
the
access
hole
above
the
cassette
compartment.
a)
Demagnetize
the
erase
and
record/playback
heads.
b)
Insert
an
azimuth-adjustment
cassette,
or
a
cassette
recorded
with
a
10
KHz
sinewave
signal,
and
connect
a
dual-channel
oscilloscope
(in
chopping
mode)
to
the
outputs
L
and
R.
c)
In
the
PLAY
mode,
turn
the
right-hand
mounting
screw
of
the
record/playback
head
(Fig.
9)
to
achieve
the
maximum
output
voltage
and
the
identical
phase
in
both
channels.
Avoid
secondary
volt-
age
maxima!
RECORD/PLAYBACK
ELECTRONICS
Before
checking
the
performance
of
the
record/playback
system,
verify
the
correct
head
bracket
height
according
to
Section
4.
Demagnetize
the
heads
and
clean
with
alcohol.
The
tests
and
calibration
procedures
are
to
be
carried
out
in
the
order
presented.
Measurement
points
MP
1
-
MP
4
are
located
on
circuit
board
VM
1.
The
location
of
other
measurement
points
and
electronic
components
is
given
by
the
first
or
the
first
two
identifying
numerals;
thus,
R
1513
is
located
on
board
VM
15,
etc.
All
voltage
specifications
are
referred
to
0
V.
Performance
Check
of
the
Record/Playback
Electronics
a)
Switch
in
the
ultrasonic
filter
(20
Hz
-
20
KHz:
linear)
of
the
audio
millivoltmeter
intended
for
the
measurements.
b)
Feed
in
a
333
Hz
sinewave
signal
and
set
the
voltage
level
at
MP
1
(L)
and
MP
2
(R)
to
-30
dBm
(app.
25
mV)
with
the
signal
generator
or
the
INPUT
level
controls.
The
voltage
amplification
of
the
Dolby
record
board
VM
6/A
is
approximately
29
dB,
so
that
a
signal
level
of
about
1
mV
should
be
measured
at
points
S
612
(L)
and
S
603
(R).
~
The
voltage
leveis
at
MP
1
and
MP
2
and
at
S
614
(L)
and
S
605
(R)
should
be
approximately
the
same.
c)
Check
the
BIAS/EQ
switching
at
board
VM
8:
Voltage
Level
at:
S
808
(L)
/
S
806
(R)
$
811
(L)
/S
802
(R)
for:
FeCr
app.
4.5
mV
50
mV
Fe
5.0
mV
55
mV
Cr
8.5
mV
95
mV
d)
Insert
an
unrecorded
cassette,
set
the
BIAS/EQ
selector
to
the
appropriate
position,
and
press
the
REC
and
PLAY
buttons
simultaneously.
Switch
off
the
filter
at
the
millivoltmeter
and
measure
the
100
KHz
voltage
at
VM
10:
S
1004
(Bias
Voltage)
S
1003
(Erase
Voltage)
for:
FeCr
47
Vrms
37
Vos
Fe
33
Vams
28
Vrms
Cr
57
Vrams
45
Veams
Switch
in
the
filter
at
the
millivoltmeter
for
the
remaining
measurements
below.