1919
Symptom Check Action
Reference
page
Water does not dispense
using electric dispense
key.
Are the mesh filter or the inside pump dirty? Clean the unit with Citric Acid.
17
Display panels are fogged
up.
Was the unit placed in an area prone to
become wet or an area where the bottom
can get wet?
Discard water, unplug, and leave until the
panels are clear.
If you still have cloud in the water scale,
please contact customer service.
-
Has the unit been placed upside down?
When refilling with water, was water
splashed onto the operation panel?
Display Message
Symptom Check Action
Reference
page
The unit is equipped with Dry-Boil Protection.
Boil lamp and Keep Warm lamp flash alternately
and signs (as shown) appear on the display.
Is there no water or very little
water in the container?
Unplug, and refill to above the
refill level of the water volume
indicator. Leave as is for a while,
then plug in.
10
Has the unit been left for a
prolonged period after all of the
hot water was dispensed, or has
lid been left open while refilling
with water?
When refilling, is water being
poured with excessive force?
Unplug, leave for a while, then
plug in.
Boiling Lamp and Keep Warm
Lamp flash alternately will appear
on the display as shown on right.
-
When refilling or cleaning the
heater, water may get inside the
unit and cause problems. Request
repair work from the Tiger product
retailer where the appliance was
purchased.
-
Specifications
3.0 L Type 4.0 L Type
Capacity
3.0 L 4.0 L
Power source
AC 120 V 60 Hz
Power consumption
Rated power
682 W
Power for the warmer
65 W
Exterior size (approximate)
(with the handle pushed down)
(inch/cm)
Width
8.4/21.2
Depth
11.0/28.0
Height
11.6/29.4 13.6/34.4
Weight (approximate) (including power cord) (lbs/kg)
5.1/2.3 5.5/2.5
Specified functions cannot be guaranteed in some areas (high altitude, extremely cold regions, etc.) Avoid using the unit in such locations.
FlashingFlashing FlashingFlashing
FlashingFlashing
9