6-2
28009-09 09/16VERSALIFT SST-37/40-EIH
DAILY VISUAL INSPECTION
slave cylinder, hoses, and fi ttings for damage, wear, or
foreign objects which may prevent proper operation.
Refer to Parts & Assemblies Section of the SST-
37/40-EIH Service Manual for these components.
DECALS - Identifi cation, operational, and instructional
decals are installed at numerous locations on the
Versalift. These decals must be replaced if they
become lost, damaged, or illegible. Refer to the
“Decal Placement” illustration in this section.
FIBERGLASS BOOMS - Inspect the fi berglass outer/
inner boom and the lower boom for an accumulation
of dirt that can impair the insulating value of the
fi berglass. The fi berglass outer surface of the
booms should be cleaned daily with a lint free cloth.
If the fi berglass sections require a more thorough
cleaning, refer to Service Procedure Section “Care
of Fiberglass Booms” of the SST-37/40-EIH Service
and Installation Manual. Check for any structural
damage in the fi berglass, such as cracks or gouges.
If these conditions exist, they must be repaired by
qualifi ed personnel.
PLATFORM - Inspect the platform for cracks in
the mounting ribs, fl oor, and fl ange around the top.
If these conditions exist they must be repaired by
qualifi ed personnel before opera tion.
SLOPE INDICATORS - The indicators are installed
at several locations on the Versalift chassis. Check
that indicators are in place and not damaged. Refer
to slope indicator installation in the Service Manual.
SAFETY DEVICES - Check visual and audible safety
devices for proper operation.
COVERS - Inspect all covers to make sure they are
in place, secure, and in good condition.