2
CE Compliant
Dimensions (H x W x D): 90 x 90 x 60mm
Multiple PIR Sensor Switching: A maximum of 8 SLFM360N PIR sensors
can be wired in parallel, to enable any
detector to turn ON all the lights connected.
The total load must not exceed the lamp
rating of a single SLFM360N unit.
4. Selecting a Location
The motion detector has a number of detection zones, at various vertical
and horizontal angles as shown (See diagram A”).
The best all-round coverage is achieved with the unit mounted
at the optimum height of 3 metres.
Careful positioning of the sensor will be required to ensure optimum
performance (see diagrams A & “B” detailing detection range
and direction).
The sensor is more sensitive to movement ACROSS its field of vision
than to movement directly TOWARDS IT (see diagram “B”).
Therefore position the unit so that the sensor looks ACROSS
the likely approach path.
Avoid positioning the sensor where there are any sources of heat
in the detection area (fans, radiators, heaters etc.) including opposite
any other light sources.
Reflective surfaces (i.e. white-painted walls, windows) may cause
false activation.