8
7. Transmitter DIP Switch Settings
The temperature swing can be adjusted between 0.5°C and 1.0°C by
selecting the desired DIP switch position found on the rear of the unit.
We suggest using 0.5°C position unless the boiler turns ON and OFF too
rapidly. A reset will be required after changing the DIP switch positions.
The OST ‘Optimal Start Time’ can also be selected ON or OFF using the
DIP switches on the rear of the unit. When set to the ON position, the
heating will turn on 20 minutes earlier, for every 1°c below your chosen
set point. A reset will be required after changing the DIP switch positions.
TRT037N Rear of Transmitter
DIP switch position label
DIP switch for temperature
swing adjustment setting
DIP switch for OST setting