Getting started...
EN
19
In more detail...
Product functions
WARNING! Apart from the testing mentioned above, do not tamper
with the safety valve. Risk of injury and property damage!
Never use the product with a defective or damaged safety valve.
In case the safety valve appears damaged or malfunctioning, have it
checked and repaired by a specialist before using the product again!
Air pressure measurement
The product can measure air pressure without being connected to the power
supply.
> Insert a suitable attachment tool onto the product (see Operation - Attachment
tools).
>
> Read the value on the pressure gauge.
>
tool from the product.
4/19/17 4:36 PM
EN
TTB797CPR
by TITAN
7.1
Fig. 3
proper levels, the safety valve is automatically deactivated. If the Safety Valve is
activated, a hissing noise will be heard. This will stop when the pressure has
been released.
To check the operation of the safety valve, carry out the following procedure.
With the compressor charged, open the relief nut (7.1) until a hissing sound is
heard. Once this sound is heard, do not open the valve any further.
Fully re-tighten the relief nut (7.1) on completion of this check.
This check should be carried out on a monthly basis to ensure continued
operation of the valve.
7
Fig. 4