V4-007 J EN
Originalbetriebsanleitung
33
8.12
High-lift spring safety relief valve
Please observe the instructions of the unit manufacturer!
If the equipment downstream of this point does not feature protection to the same •
standard, you must install another safety relief valve after the non-return valve.
There must not be a shut-off device between the valve and the compressor. •
The valve is not a regulating device and must not be used as such. •
The valve is set to the following recommand values:•
- VML compressors pe = 2.8 bar
Check that the valve is functioning correctly at the intervals specied on the main-•
tenance schedule by opening it manually.
CAUTION! Hot air will escape while the valve is open.