34
Drive coupling
Please observe the instructions of the unit manufacturer!
Whenever work is carried out on the drive coupling, the machine must be taken
out of operation and correctly isolated from the mains supply.
The machine must be prevented from starting up/being operated.
Caution: The coupling is potentially dangerous and can sever and/or crush
body parts.
Please check the alignment of the drive coupling prior to rst •
commissioning.
The service life of the drive elements will be affected depending on the extent of •
any misalignments.
If necessary, the alignment should be corrected. •
There should be no large gaps or holes present with coupling guards that have •
been correctly mounted. The coupling guard must prevent contact occurring inad-
vertently with the drive coupling during operation.
CAUTION! Risk of injury due to rotating components!
Once rst commissioning has been carried out and the machine has been running •
for approx. 3 hours, the coupling alignment should be checked again.
8.13
Property of American Airlines