Steps for correct programming:
08. TM63 / TM68 / TM69 WATER SOFTENER START-UP
1. Program indicator
2. Minutes indicator
3. Seconds indicator
4. Days / gallons
5. Hours / m
3
6. Minutes / liters
7. Service
8. Backwash
9. Aspiration brine
10. Load brine
11. Fast rinse
12. Schedule
13. Block
14. Programming mode
15. Menu / confirmation
16. Manual regeneration
17. Down
18. Up
14
11
1 2 3
4
5
6
9
10
171615 18
1312
87
All valves are shipped with a standard configuration.
However, you can adjust this schedule according to the needs and water quality of the area.
TM68 / TM69 valve programmation:
1. Unlock and access to programmation:
To unlock and enter the manual mode and program changes, press the UP and DOWN buttons simulta-
neously until the key icon desappears and appears the tool icon (setting mode).
2. Set the clock valve:
Press the button “Menu/confirm” twice, and use the buttons UP and DOWN to set the clock at the hour.
Press again the button “Menu/confirm” and you’ll be able to change the minutes. Finally, press “Menu/con-
firm” and the time will be set.