EasyManua.ls Logo

TM TM63 LED - Page 24

TM TM63 LED
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
ENGLISH
23
Press “Menu/confirm” and use UP and DOWN to set the number of days you wish, between 00 and 40. That
is preset at 30 days. Press “Menu/confirm” to confirm.
Button “UP”
Button “DOWN”
Button “MENU”
Button “MENU”
11. Maximum days between regenerations H- :
Press the button DOWN, the screen will show H- (maximum days between regenerations).
These are number of days that if there is no water consumption after the days we have scheduled, there will
be a maintenance regeneration.
Table 2. Regeneration time for each cycle (using standard resine as reference) at 3 bars entry pressure.
Regeneration times according to liters of resin in the bottle
7
14
20
22
30
35
3 min.
3 min.
3 min.
3 min.
3 min.
3 min.
Liters of
resin
Bottle
First cycle:
backwash
Programa 2
25 min.
30 min.
30 min.
30 min.
45 min.
45 min.
Second cycle:
aspiration of brine
Programa 3
1 min.
2 min.
3 min.
3 min.
4 min.
4 min.
Third cycle:
brine load
Programa 4
3 min.
3 min.
3 min.
3 min.
3 min.
3 min.
Fourth cycle:
Quick wash
Programa 5
07x17
10x17
08x35
08x35
10x35
10x35
Injector according
to bottle Ø
Pink
White
Yellow
Yellow
White
White